The DAQPad-1200 is identified by its part number 766080-01 and falls under the category of Legacy DAQ Devices. This device is particularly distinct due to its description as a FUSE,SM,400MA,63V,W/HOLDER, showcasing its unique specifications and applications. An array of power options are available for this device, including part numbers 776895-01 for the US 120 VAC, 776895-06 for the UK 240 VAC, and 776895-31 for the Universal Euro 240 VAC.
The DAQPad-1200 boasts a Parallel Port communication interface, which supports both Standard and Enhanced modes. Its flexibility in data acquisition is evident from its analog input channels, which can be configured as either 8 single-ended or 4 differential channels, according to the requirements of the programmable settings. This device is compatible with a wide range of software including LabVIEW, LabWindows/CVI, Lookout, BridgeVIEW, Measure, ComponentWorks, and VirtualBench, and is supported by NI-DAQ software.
For power supply, users can choose from an AC Adapter, a BP-1 battery pack (rechargeable), or a 9 – 42 VDC power source, providing flexibility in operation environments. The DAQPad-1200 also offers software selectable gains of 1, 2, 5, 10, 20, 50, 100, accommodating a wide range of signal amplification needs. It can handle both Unipolar and Bipolar analog input signal ranges, ensuring versatility in data acquisition tasks. Moreover, the device is equipped with self-calibration capability, enhancing its accuracy and reliability over time.
| Specification | Details |
|---|---|
| Part Number | 766080-01 |
| Category | Legacy DAQ Devices |
| Model | DAQPad-1200 |
| Description | FUSE,SM,400MA,63V,W/HOLDER |
| Power Options Part Numbers | 776895-01 (US 120 VAC), 776895-06 (UK 240 VAC), 776895-31 (Universal Euro 240 VAC) |
| Communication Interface | Parallel Port (Standard and Enhanced) |
| Analog Input Channels | 8 single-ended or 4 differential (programmable) |
| Compatible Software | LabVIEW, LabWindows/CVI, Lookout, BridgeVIEW, Measure, ComponentWorks, VirtualBench |
| Supported NI Software | NI-DAQ |
| Power Supply Options | AC Adapter, BP-1 battery pack (rechargeable), 9 – 42 VDC power source |
| Software Selectable Gains | 1, 2, 5, 10, 20, 50, 100 |
| Analog Input Signal Ranges | Unipolar and Bipolar |
| Calibration | Self-calibration capability |
Answer 1: 766080-01
Question 2: How many analog inputs does the DAQPad-1200 have?
Answer 2: 8 single-ended or 4 differential
Question 3: What type of communication does the DAQPad-1200 use?
Answer 3: Parallel Port
Question 4: Is the DAQPad-1200 compatible with LabVIEW?
Answer 4: Yes, among other NI software
Question 5: What are the power options for the DAQPad-1200?
Answer 5: AC Adapter, BP-1 battery pack, 9-42 VDC