Description
The NI 5102 for PCMCIA, part number 18344.2, is a high-performance oscilloscope instrument designed for a variety of testing applications. Manufactured by National Instruments, this device falls under the category of PC-based Oscilloscopes/Digitizers and is part of the DAQScope family. It utilizes a PCMCIA bus interface, making it an ideal solution for portable field test, power supply testing, high-speed waveform capture, transmission line testing, and electronic testing among other applications.
The DAQCard-5102 model boasts 2 input channels with an 8-bit resolution, providing precise measurements for your testing needs. It supports a range of triggers including 1 analog and 2 digital triggers, ensuring flexibility in capturing signal events. With an input bandwidth of 15 MHz and a sampling rate that varies from 20 MS/s to 1 kS/s, it is capable of handling a wide range of signal frequencies. Additionally, it features a substantial memory depth of 662 ksamples, allowing for extended data capture periods.
For connectivity, the DAQCard-5102 requires the NI-Scope driver and is compatible with a variety of software including Measurement Studio, LabWindows, LabVIEW, Visual Basic, and C/C++. It is designed to operate seamlessly with Windows NT/2000/XP operating systems. The input coupling is software-selectable AC/DC, providing users with the flexibility to adjust settings based on the specific requirements of their testing scenario. The analog trigger features include hysteresis, software-selectable level, and slope, while the digital triggers are compatible with standard TTL/CMOS.
Before reaching its optimum performance, the DAQCard-5102 requires a warm-up time of 15 minutes. Whether you are conducting portable field tests or engaging in complex electronic testing, this oscilloscope instrument offers the reliability, flexibility, and performance needed to achieve accurate results.
| Specification | Detail |
|---|---|
| Part Number | 18344.2 |
| Category | PC-based Oscilloscopes/Digitizers |
| Model | DAQCard-5102 |
| Description | NI 5102 for PCMCIA, 20 MS/s Oscilloscope Instrument |
| Manufacturer | National Instruments |
| Family | DAQScope |
| Bus Interface | PCMCIA |
| Input Channels | 2 |
| Resolution | 8 bits |
| Triggers | 1 analog and 2 digital |
| Input Bandwidth | 15 MHz |
| Driver Requirement | NI-Scope driver |
| Software Compatibility | Measurement Studio, LabWindows, LabVIEW, Visual Basic, C/C++ |
| Operating Systems | Windows NT/2000/XP |
| Sampling Rate | 20 MS/s to 1 kS/s |
| Memory Depth | 662 ksamples |
| Coupling | Software-selectable AC/DC |
| Analog Trigger Features | Hysteresis, software-selectable level and slope |
| Digital Triggers | 2 |
| Digital Trigger Compatibility | Standard TTL/CMOS |
| Applications | Portable field test, power supply testing, high-speed waveform capture, transmission line testing, electronic testing, etc. |
| Warm-up Time | 15 minutes | Question 1: What is the maximum sampling rate of DAQCard-5102?