Description
The DAQCard-5102 is a PC-based oscilloscope/digitizer part, identified by its part number 777251-02. Manufactured by National Instruments, this device falls under the category of PC-based Oscilloscopes/Digitizers. It connects to a computer via a PCMCIA bus interface, making it highly versatile for portable applications.
It features 2 input channels with an 8-bit resolution, providing a decent balance between precision and speed for a variety of signal analysis tasks. The DAQCard-5102 is capable of handling 1 analog and 2 digital triggers, allowing for flexible signal acquisition setups. With an input bandwidth of 15 MHz, it can accurately capture high-frequency signals.
The device boasts a variable sampling rate ranging from 20 MS/s to 1 kS/s, accommodating both high-speed and slow, detailed signal analysis without compromising data integrity. It also comes with a generous memory depth of 662 ksamples, ensuring that users can store substantial amounts of data for analysis.
Signal coupling is software-selectable between AC and DC, providing users with the flexibility to adapt to different signal types. The trigger types supported are standard TTL/CMOS digital, which are common and widely used in various applications.
Compatibility with software is broad; the DAQCard-5102 supports Measurement Studio, LabWindows, LabVIEW, Visual Basic, and C/C++, making it a versatile tool that can be integrated into a wide range of development environments. It is also compatible with Windows NT/2000/XP operating systems, ensuring it can be used with a variety of computer systems.
Regarding power consumption, it operates efficiently at 5 VDC, with a typical current draw of 260 mA. To ensure accurate measurements, a warm-up time of 15 minutes is recommended.
| Specification | Detail |
|---|---|
| Part Number | 777251-02 |
| Category | PC-based Oscilloscopes/Digitizers |
| Model | DAQCard-5102 |
| Manufacturer | National Instruments |
| Bus Interface | PCMCIA |
| Input Channels | 2 |
| Resolution | 8 bits |
| Triggers | 1 analog and 2 digital |
| Input Bandwidth | 15 MHz |
| Sampling Rate | 20 MS/s to 1 kS/s |
| Memory Depth | 662 ksamples |
| Coupling | Software-selectable AC/DC |
| Trigger Types | Standard TTL/CMOS digital |
| Software Compatibility | Measurement Studio, LabWindows, LabVIEW, Visual Basic, C/C++ |
| Operating Systems Compatibility | Windows NT/2000/XP |
| Power Consumption | 5 VDC, 260 mA typical |
| Warm-up Time | 15 minutes (recommended) |
Question 1: What is the part number of DAQCard-5102?
Answer 1: The part number is 777251-02.
Question 2: How many input channels does DAQCard-5102 have?
Answer 2: It has 2 input channels.
Question 3: What is the input bandwidth of the DAQCard-5102?
Answer 3: It has a 15 MHz input bandwidth.
Question 4: What software supports the DAQCard-5102?
Answer 4: Supports LabVIEW, Visual Basic, C/C++, and others.
Question 5: What is the power consumption of DAQCard-5102?
Answer 5: Consumes 5 VDC, with a typical current of 260 mA.