Description
The DAQPad-6016, identified by part number 782991-01, falls within the category of Legacy DAQ Devices. This device offers a seamless connection via USB and is compatible with an array of software including NI-DAQmx, LabView, VI Logger, Measurement Studio, Lab Windows/CVI, C++, C#, and Visual Basic. With its 16 analog inputs and 2 analog outputs, it provides significant flexibility for various data acquisition tasks.
In addition to the analog interfaces, the DAQPad-6016 features 32 I/O lines, enhancing its utility for more complex setups. It is designed to operate efficiently with Windows 2000/XP operating systems, making it suitable for a wide range of applications in environments utilizing these systems. The device dimensions are specified as 191 mm x 163 mm and 111 mm x 163 mm, providing compact and versatile options for installation.
Moreover, the DAQPad-6016 is equipped with LED indicators to signify operational status: a Green LED for READY and a Yellow LED for ACTIVE status. Each LED is paired with a 220 Ω resistor, labeled as R5 for the READY indicator and R6 for the ACTIVE indicator, ensuring proper functioning and longevity of these visual cues.
| Specification | Detail |
|---|---|
| Part Number | 782991-01 |
| Category | Legacy DAQ Devices |
| Model | DAQPad-6016 |
| Connection Type | USB |
| Software Compatibility | NI-DAQmx, LabView, VI Logger, Measurement Studio, Lab Windows/CVI, C++, C#, Visual Basic |
| Number of Analog Inputs | 16 |
| Number of Analog Outputs | 2 |
| Number of I/O Lines | 32 |
| Operating Systems Supported | Windows 2000/XP |
| Dimensions | 191 mm x 163 mm and 111 mm x 163 mm |
| LED Indicators | 1 Green (READY), 1 Yellow (ACTIVE) |
| Resistor for READY LED | 220 Ω (R5) |
| Resistor for ACTIVE LED | 220 Ω (R6) |
Question 1: What is the part number for DAQPad-6016?
Answer 1: 782991-01
Question 2: How many analog inputs does DAQPad-6016 have?
Answer 2: 16
Question 3: What operating systems is the DAQPad-6016 compatible with?
Answer 3: Windows 2000/XP
Question 4: What type of software can be used with DAQPad-6016?
Answer 4: NI-DAQmx, LabView, C++, Visual Basic, etc.
Question 5: What are the dimensions of DAQPad-6016?
Answer 5: 191 mm x 163 mm and 111 mm x 163 mm