Description
The DAQPad-6020E is categorized under Legacy DAQ Devices and features a variety of part numbers which include 777474-01, 777474-04, 777474-06, 777474-07, 777704-01, 777704-04, 777704-06, 777704-07, 777703-01, 777703-04, 777703-06, and 777703-07. It is designed to be compatible with multiple operating systems such as Windows NT/2000/XP, Linux, and Mac OS X, ensuring a wide range of usability across different platforms.
For software support, the DAQPad-6020E is compatible with LabVIEW, LabWindows, VI-Logger, Measurement Studio, Visual Basic, C++, and C#, providing flexibility for developers and engineers in choosing their preferred programming environments. The device operates with NI-DAQ 7 drivers, ensuring smooth integration and operation within systems.
This device utilizes a USB interface for connectivity, making it easily connectable to a variety of computing devices. It comes in two enclosure lengths, 30 cm and 15 cm, to suit different space requirements. The connector type employed is a 68-pin male 0.050 D-type I/O, which allows for secure and reliable connections.
With 8 differential analog input channels, offering 12-bit resolution, the DAQPad-6020E is capable of handling detailed data acquisition tasks. It supports a maximum sampling rate of 100 kS/s, enabling rapid data collection. The input voltage range of ±0.05 to ±10 V allows for a wide range of sensor and signal types to be accommodated.
Additionally, the device features 2 analog output channels, also with 12-bit resolution, providing precise control over output signals. This combination of features makes the DAQPad-6020E a versatile tool for a wide range of data acquisition and control applications.
| Specification | Detail |
|---|---|
| Part Numbers | 777474-01, 777474-04, 777474-06, 777474-07, 777704-01, 777704-04, 777704-06, 777704-07, 777703-01, 777703-04, 777703-06, 777703-07 |
| Category | Legacy DAQ Devices |
| Model | DAQPad-6020E |
| Compatibility | Windows NT/2000/XP, Linux, Mac OS X |
| Software Support | LabVIEW, LabWindows, VI-Logger, Measurement Studio, Visual Basic, C++, C# |
| Driver | NI-DAQ 7 |
| Interface | USB |
| Enclosure Length | 30 cm, 15 cm versions |
| Connector Type | 68-pin male 0.050 D-type I/O |
| Analog Input Channels | 8 differential, 12-bit resolution |
| Maximum Sampling Rate | 100 kS/s |
| Input Voltage Range | ±0.05 to ±10 V |
| Analog Output Channels | 2, 12-bit resolution |