Description
The DAQPad-6052E Multifunction I/O Device, manufactured by National Instruments, comes with a variety of part numbers including 778535-01, 778535-04, 778535-06, 778536-01, 778536-04, and 778536-06. This device is designed to cater to various data acquisition needs with its 16 single-ended or 8 differential input channels.
It features a high-quality 16-bit Analog to Digital Converter (ADC) and 16-bit voltage output Digital to Analog Converter (DAC), ensuring accurate data conversion for both input and output signals. The device is equipped with two 24-bit counters/timers for Timing I/O (TIO), enhancing its functionality in complex timing applications.
For connectivity, the DAQPad-6052E utilizes a FireWire (IEEE 1394) interface, allowing up to 64 devices to be connected to a single computer using IEEE 1394, which is ideal for scalable applications. The device offers various termination options, including mass termination or BNC termination, providing flexibility in connecting different types of sensors and signals. Moreover, its power options are country-specific, catering to global power supply standards.
It supports a wide range of development environments such as LabVIEW, CVI, Visual C++, and Data Acquisition Easy I/O Libraries, making it versatile for various programming needs. With a sampling rate of up to 333kS/s and a FIFO buffer size of 512 samples, the DAQPad-6052E is capable of handling high-speed data acquisition tasks efficiently.
| Specification | Detail |
|---|---|
| Part Numbers | 778535-01, 778535-04, 778535-06, 778536-01, 778536-04, 778536-06 |
| Manufacturer | National Instruments |
| Device Type | DAQPad-6052E Multifunction I/O Device |
| Termination Options | Mass termination or BNC termination |
| Power Options | Country-specific |
| Analog to Digital Converter (ADC) | 16-bit |
| Digital to Analog Converter (DAC) | 16-bit voltage outputs |
| Counters/Timers | Two 24-bit for TIO |
| Interface | FireWire (IEEE 1394) |
| Maximum Number of Devices per Computer | 64 using IEEE 1394 |
| Development Environments | LabVIEW, CVI, Visual C++, Data Acquisition, Easy I/O Libraries |
| Sampling Rate | Up to 333kS/s |
| Channels | 16 single ended or 8 differential input channels |
| FIFO Buffer Size | 512 samples |
|
Question 1: What is the max sampling rate of DAQPad-6052E? Question 2: Does DAQPad-6052E support differential inputs? Question 3: What type of interface does the DAQPad-6052E use? Question 4: How many counters/timers does the DAQPad-6052E have? Question 5: Can the DAQPad-6052E be used in global applications? |