Description
The product with the part number 777405-01 falls under the category of Legacy DAQ Devices. It is a DAQPad-6507 model, manufactured by National Instruments. This device boasts 96 Digital Input/Output channels, making it versatile for various data acquisition tasks. It incorporates a Programmable Peripheral Interface that includes four 82C55A chips, enhancing its functionality.
With a maximum transfer rate of 60 S/s, it ensures efficient data management. The DAQPad-6507 connects via a USB interface, offering easy integration with most computer systems. Its power requirements are quite flexible, needing 4.40 to 5.25 VDC with a typical current of 220 mA and a maximum of 500 mA when powered through USB. For external power sources, it requires 9 to 30 VDC, with a maximum consumption of 12 W.
This device supports 2 wire protocol handshaking, ensuring reliable communication between devices. It is compatible with a variety of programming environments, including NI-DAQ for PC Compatibles, LabVIEW for Windows, LabWindows/CVI, ComponentWorks, and VirtualBench. For driver software, it is compatible with NI-DAQ 6.0 or 6.1 for Windows 95, and NI-DAQ 6.5 or later for Windows 98, ensuring wide usability across different operating systems.
One of the notable features of the DAQPad-6507 is that it is software configurable, offering flexibility in its use. Additionally, it supports hot plug and play, making it convenient for users to connect and disconnect the device without having to reboot the connected computer or system.
| Specification | Detail |
|---|---|
| Part Number | 777405-01 |
| Category | Legacy DAQ Devices |
| Model | DAQPad-6507 |
| Manufacturer | National Instruments |
| Channels | 96 Digital Input/Output |
| Programmable Peripheral Interface | Four 82C55A |
| Maximum Transfer Rate | 60 S/s |
| Interface | USB |
| Power Requirements (USB) | 4.40 to 5.25 VDC; 220 mA typical, 500 mA maximum |
| Power Requirements (External) | 9 to 30 VDC; 12 W maximum |
| Handshaking | 2 wire protocol |
| Programming Compatibility | NI-DAQ for PC Compatibles, LabVIEW for Windows, LabWindows/CVI, ComponentWorks, VirtualBench |
| Driver Software Compatibility | NI-DAQ 6.0 or 6.1 for Windows 95, NI-DAQ 6.5 or later for Windows 98 |
| Features | Software configurable, Hot plug and play |
|
Question 1: What is the part number of the DAQPad-6507? Question 2: How many DI/O channels does the DAQPad-6507 have? Question 3: What is the max transfer rate of DAQPad-6507? Question 4: What programming environments is DAQPad-6507 compatible with? Question 5: Does the DAQPad-6507 support hot plug and play? |