img

148641B-01L

The FieldDAQ FD-11605 by National Instruments is an 8-channel, ±60 V filtered voltage input device, with a 100 kS/s sampling rate and IP67 rating.

In Stock | Ships Today

img

    Description

    The product with the part number 786469-01 falls under the Category of FieldDAQ and is designated with the model number FD-11605. This device is primarily a Voltage Input Device, Analog Board, meticulously engineered by National Instruments. It’s part of the broader FD-116x family and is configured to operate with the NI-DAQmx driver, ensuring seamless integration and functionality.

    The device boasts 8 channels, catering to a wide range of input and measurement needs. It can handle an input voltage of ±60 V filtered, making it versatile for various applications. Remarkably, the device does not require an external power supply for its instrument hardware, enhancing its convenience and usability.

    In terms of safety and reliability, it features channel-to-channel isolation up to 1000 V, ensuring that signal integrity is maintained and protected across channels. The device is capable of a sampling rate of 100 kS/s, allowing for high-speed data acquisition and processing.

    It is designed with an Ingress Protection Rating of IP67, indicating its robustness and ability to withstand harsh environmental conditions. Networking is facilitated through an integrated switch with TSN (Time-Sensitive Networking), and its daisy-chaining capability is supported by internal circuitry, simplifying setup and expansion.

    The operating temperature range of the device is from -40 to 85 °C, demonstrating its reliability and performance stability in extreme conditions. This combination of features makes the FD-11605 an ideal choice for a wide range of applications requiring precise voltage input measurement and robust performance.

    Specification Detail
    Part Number 786469-01
    Category FieldDAQ
    Model FD-11605
    Description Voltage Input Device, Analog Board
    Manufacturer National Instruments
    Family FD-116x
    Configuration NI-DAQmx driver
    Channels 8
    Input Voltage ±60 V filtered
    Power Supply None required for instrument hardware
    Isolation Channel-to-channel, up to 1000 V
    Sampling Rate 100 kS/s
    Ingress Protection Rating IP67
    Networking Integrated switch with TSN
    Daisy-Chaining Internal circuitry
    Operating Temperature -40 to 85 °C

    Question 1: What is the input voltage range of the FD-11605?
    Answer 1: ±60 V filtered

    Question 2: What IP rating does the FD-11605 have?
    Answer 2: IP67

    Question 3: What is the sampling rate of the FD-11605?
    Answer 3: 100 kS/s

    Question 4: Does the FD-11605 require an external power supply?
    Answer 4: No

    Question 5: What’s the operating temperature range for FD-11605?
    Answer 5: -40 to 85 °C