777517-01

The FP-1001 is a FieldPoint RS485 network module with optical isolation, supporting up to 25 units per port and a max cabling distance of 4000 ft.

In Stock | Ships Today

img

    Description

    The FP-1001 RS485 Network Module, part number 777517-01, falls under the FieldPoint category and is identified by the model FP-1001. It is noted for its use in facilitating RS-485, Full-duplex mode communications but is marked as “Not for New Design”, suggesting that it may be nearing the end of its product lifecycle or is intended for legacy systems.

    This module boasts optical isolation for enhanced electrical isolation between devices on a network. It supports a maximum of 25 FP-1001 network modules per RS-485 port, allowing for significant expansion capabilities in complex systems. Configuration is made straightforward through the use of switches 1 to 5 for address setting, making it adaptable to various network configurations.

    It requires a power supply within the range of 11–30 VDC and is compatible with a variety of programming software options including LabVIEW VIs, LabWindows/CVI functions, FieldPoint Explorer Configuration Utility, Lookout Driver Class, and OPC server. This wide range of software compatibility underscores the module’s versatility in application development and system integration.

    The module supports multiple baud rates (switch-settable) ranging from 300 to 115200, allowing for flexible communication speed settings based on the specific requirements of a given application. It can manage a maximum cabling distance of 4000 ft from the host, providing substantial reach for extended network configurations.

    With a weight of 8.4 oz and an operating temperature range of –40 to +70 °C, the FP-1001 is built to withstand challenging industrial environments, making it a reliable component for a wide range of applications.

    < Question 1: What is the part number for the FP-1001?
    Answer 1: The part number is 777517-01.

    Question 2: How many FP-1001 units can be supported per port?
    Answer 2: Up to 25 units per RS-485 port.

    Question 3: What is the maximum cabling distance for the FP-1001?
    Answer 3: The maximum distance is 4000 ft.

    Question 4: What power supply range does the FP-1001 require?
    Answer 4: It requires 11-30 VDC.

    Question 5: Is optical isolation a feature of the FP-1001?
    Answer 5: Yes, it features optical isolation.

    Specification Detail
    Part Number 777517-01
    Category FieldPoint
    Model FP-1001
    Description FP-1001 RS485 Network Module (Not for New Design)
    Communication Protocol RS-485, Full-duplex mode
    Optical Isolation Yes
    Maximum Number of FP-1001 Network Modules per RS-485 Port 25
    Address Setting Switches 1 to 5
    Power Supply Requirement 11–30 VDC
    Programming Software LabVIEW VIs, LabWindows/CVI functions, FieldPoint Explorer Configuration Utility, Lookout Driver Class, OPC server
    Baud Rates (switch-settable) 300, 1200, 2400, 9600, 19200, 38400, 57600, 115200
    Maximum Cabling Distance 4000 ft from host
    Weight 8.4 oz
    Operating Temperature Range –40 to +70 °C