Description
“`html
The device comes with a variety of Part Numbers, including 779516-01, 783731-01, and 779516-02, catering to different needs with specific connector types. It is equipped with 8 single-ended analog input channels, providing flexibility for multiple data acquisition tasks.
With a resolution of 16 bits, it ensures high precision in data capture. The system can handle a Maximum Sampling Rate of 200 kS/s, allowing for the efficient processing of fast-changing signals.
The Input Range is quite broad, from -20 mA to 20 mA, accommodating a variety of signal types. Furthermore, it boasts Isolation of 250 Vrms, channel-to-ground, ensuring safety and reducing noise interference in measurements.
To protect against unexpected voltage spikes, each channel is equipped with Overvoltage Protection of ±30 V. The device offers multiple Connector Types, including Screw Terminal (779516-01), Spring Terminal (783731-01), and Conformal Coated Screw Terminal (779516-02), providing versatility in connection options.
It is compatible with various software, including NI-DAQmx 9.2, LabVIEW, LabWindows/CVI, C/C++, C#, and Visual Basic .NET, ensuring seamless integration into existing systems. The Gain Error is minimal at ±0.04% (at 25°C, ±5°C), and the Offset Error is even lower at ±0.02% (at 25°C, ±5°C), indicating high accuracy in measurements.
The Power Consumption is efficient, with only 399 mW (Active), and drops significantly to 5 mW (Sleep), making it an energy-efficient choice. The Minimum Conversion Time is 5.2 µs (with R Series Expansion Chassis), highlighting its quick data
| Specification | Detail |
|---|---|
| Part Numbers | 779516-01, 783731-01, 779516-02 |
| Channels | 8 single-ended analog input channels |
| Resolution | 16 bits |
| Maximum Sampling Rate | 200 kS/s |
| Input Range | -20 mA to 20 mA |
| Isolation | 250 Vrms, channel-to-ground |
| Overvoltage Protection | ±30 V for each channel |
| Connector Types | Screw Terminal (779516-01), Spring Terminal (783731-01), Conformal Coated Screw Terminal (779516-02) |
| Software Compatibility | NI-DAQmx 9.2, LabVIEW, LabWindows/CVI, C/C++, C#, Visual Basic .NET |
| Gain Error | ±0.04% (at 25°C, ±5°C) |
| Offset Error | ±0.02% (at 25°C, ±5°C) |
| Power Consumption | 399 mW (Active), 5 mW (Sleep) |
| Min Conversion Time | 5.2 µs (with R Series Expansion Chassis) |
| Question 1: What are the input range limits of the NI-9203? Answer 1: -20 mA to 20 mA Question 2: How many analog input channels does NI-9203 have? Question 3: What is the max sampling rate of NI-9203? Question 4: What software is compatible with the NI-9203? Question 5: What is the power consumption in active mode for NI-9203? |