Description
The NI-9213, belonging to the C Series Analog Input category, is a Thermocouple Input Module designed to cater to a variety of temperature sensing and measurement needs. With part numbers including 780493-01, 780493-02, 785185-01, and 785185-02, this module stands out for its precision and flexibility.
It features 16 channels, allowing for extensive data collection and monitoring across multiple points simultaneously. The NI-9213 guarantees a maximum accuracy of 2.25 degrees Celsius, ensuring reliable and precise temperature readings critical for a wide range of applications.
With a sample rate of 75 Samples per second, this module offers swift data acquisition, making it suitable for dynamic and time-sensitive environments. Its autozero function further enhances measurement accuracy by compensating for any DC offsets.
The NI-9213 is designed with safety and reliability in mind, featuring 250 Vrms Ch-Earth isolation for continuous operation, ensuring the protection of both the module and the connected devices. The spring terminal connection provides a secure and easy-to-use method for attaching thermocouples.
To accommodate various environments and reduce potential interference, the module includes noise filtering for 50 Hz and 60 Hz, minimizing the impact of electrical noise on measurement accuracy. It weighs 5.6 oz, making it a lightweight but robust option for portable and stationary setups.
The NI-9213 supports high-resolution and high-speed timing modes, providing flexibility for different types of experiments and measurements. It is compatible with a wide range of software, including LabVIEW, LabWindows/CVI, Microsoft Visual C++, Visual Basic, Borland C++, and .NET, allowing for easy integration into existing systems and workflows.
Configuration and setup can be efficiently handled through the Measurement & Automation Explorer (MAX), simplifying the process of getting the module up and running. To maintain its high level of accuracy and reliability, a calibration interval of at least once per year is recommended.
Question 1: How many channels does the NI-9213 have?
Answer 1: 16 channels
Question 2: What is the max accuracy of the NI-9213?
Answer 2: 2.25 degrees Celsius
Question 3: What is the NI-9213’s sample rate?
Answer 3: 75 Samples per second
Question 4: Does the NI-9213 have noise filtering?
Answer 4: Yes, for 50 Hz and 60 Hz
Question 5: What software is the NI-9213 compatible with?
Answer 5: LabVIEW, LabWindows/CVI, Visual C++, Visual Basic, Borland C++, .NET