Description
The product comes with multiple Part Numbers including 780493-01, 780493-02, 785185-01, and 785185-02, catering to a wide range of applications and requirements. It is designed to support 16 Channels, making it versatile for complex data acquisition tasks. The system boasts an Accuracy level with a maximum deviation of 2.25°C, ensuring precise measurements across its operations.
With a Sample Rate of 75 Samples per second (S/s), this product is capable of capturing fast-changing signals with high fidelity. It also features an Autozero Function, which automatically compensates for any offset, ensuring the accuracy of measurements over time. The device is designed with Isolation capabilities of 250 Vrms Channel-to-Earth continuously, providing enhanced safety and noise immunity.
The Connection Type utilized is a spring terminal, which allows for easy and secure connections without the need for tools. It is equipped with filtering capabilities to eliminate 50 Hz and 60 Hz noise, ensuring clear signal acquisition even in electrically noisy environments. Despite its robust capabilities, the device has a lightweight design, weighing only 5.6 oz.
It supports multiple Timing Modes, including high-resolution and high-speed modes, providing flexibility in data acquisition and analysis. The product is compatible with several software platforms such as LabVIEW, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic, Borland C++, and Microsoft .NET, making it adaptable to various development environments.
To maintain its high performance, a Calibration Interval is recommended at least once a year. Its Input Circuitry includes a differential filter, multiplexing, and a 24-bit Delta-Sigma ADC, ensuring accurate signal processing and data conversion. The device can operate within a wide Operating Temperature range from -40°C to 70°C, making it suitable for use in extreme conditions. Lastly, it requires a Warm-up Time of 15 minutes to reach operational stability.
| Specification | Description |
|---|---|
| Part Numbers | 780493-01, 780493-02, 785185-01, 785185-02 |
| Channels | 16 |
| Accuracy | Maximum of 2.25°C |
| Sample Rate | 75 S/s |
| Autozero Function | Yes |
| Isolation | 250 Vrms Ch-Earth continuous |
| Connection Type | Spring terminal |
| Filtering | 50 Hz and 60 Hz noise |
| Weight | 5.6 oz |
| Timing Modes | High-resolution and high-speed |
| Software Compatibility | LabVIEW, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic, Borland C++, Microsoft .NET |
| Calibration Interval | Recommended at least once a year |
| Input Circuitry | Differential filter, multiplexing, 24-bit Delta-Sigma ADC |
| Operating Temperature | -40°C to 70°C |
| Warm-up Time | 15 minutes |