Description
The NI 9216 Spring, identified by the part number 157270D-06L and its other part numbers including 783863-01, 783863-02, 785186-01, 783664-01, falls under the category of C Series Analog Input modules. This particular model, NI-9216, is designed for precise data acquisition and measurement.
The NI 9216 boasts a high-resolution 24-bit ADC, capable of sampling at a rate of 400 samples per second. It is equipped with 8 channels, making it suitable for monitoring multiple sensors simultaneously. The module operates in modes that prioritize either a high sample rate or high resolution, providing flexibility depending on the application requirements.
Its measurement range extends from 0 to 400 ohms, catering to a wide variety of RTD sensors. The device is available in two models based on weight; the Spring Terminal Model weighs 5.7 oz, while the DSUB Model is slightly lighter at 5.04 oz. This makes the module easily integrable into various setups without significantly affecting the overall weight.
The NI 9216 is built to withstand harsh environments, operating within a temperature range of -40 °C to 70 °C and can be stored in temperatures ranging from -40 °C to 85 °C. Its humidity tolerance is also notable, supporting 10% RH to 90% RH during operation and 5% RH to 95% RH in storage conditions. These specifications ensure reliable performance in a broad range of industrial and research applications.
| Attribute | Details |
|---|---|
| Part Number | 157270D-06L (Other Part Numbers: 783863-01, 783863-02, 785186-01, 783664-01) |
| Category | C Series Analog Input |
| Model | NI-9216 |
| Description | NI 9216 Spring, 8-CH PT100 RTD 24-Bit, C Series Module |
| Resolution | 24 bits |
| Sample Rate | 400 samples per second |
| Channels | 8 |
| Operating Modes | High sample rate, High resolution |
| Measurement Range | 0 to 400 ohms |
| Weight (Spring Terminal Model) | 5.7 oz |
| Weight (DSUB Model) | 5.04 oz |
| Operating Temperature Range | -40 °C to 70 °C |
| Storage Temperature Range | -40 °C to 85 °C |
| Humidity Range | Operating: 10% RH to 90% RH, Storage: 5% RH to 95% RH |