Description
The NI-9216 is a model under the C Series Analog Input category, designed for precision and durability. It is designated with part numbers 783863-01, 783863-02, 785186-01, 783664-01, ensuring a range of options for specific needs. This module stands out for its detailed engineering, including a conformal coated, 8-channel PT100 RTD 24-bit specification, tailored for diverse industrial applications.
With an impressive sample rate of 400 samples per second and a high resolution of 24 bits, the NI-9216 is capable of delivering accurate and detailed measurements. It operates in two modes: high sample rate and high resolution, catering to different requirements of speed and precision. The conversion time in high-resolution mode is 200 ms per channel, amounting to 1600 ms for all channels, while in high-speed mode, it dramatically reduces to 2.5 ms per channel, totaling 20 ms for all channels.
The module’s resistance measurement range spans from 0 to 400 ohms, supporting a wide array of sensors and inputs. It is built to withstand harsh environments, with an operating temperature range of -40 °C to 70 °C and a storage temperature range extending from -40 °C to 85 °C. The humidity range, both for operating and storage conditions, is equally robust, ranging from 10% RH to 90% RH and 5% RH to 95% RH, respectively.
Regarding durability, the NI-9216 can handle significant vibration during operation, with a 5 grms (Random) and 5 g (Sinusoidal), across a frequency range of 10 to 500 Hz. Its weight is optimized for easy integration into systems, being 5.7 oz for the spring terminal version and 5.04 oz for the D-Sub version.
| Specification | Details |
|---|---|
| Part Numbers | 783863-01, 783863-02, 785186-01, 783664-01 |
| Category | C Series Analog Input |
| Model | NI-9216 |
| Description | NI 9216 D-Sub, Conformal Coated, 8-CH PT100 RTD 24-Bit, C Series Module |
| Channels | 8 |
| Sample Rate | 400 samples per second |
| Resolution | 24 bits |
| Operating Modes | High sample rate, High resolution |
| Conversion Time (High Resolution Mode) | 200 ms per channel, 1600 ms for all channels |
| Conversion Time (High-Speed Mode) | 2.5 ms per channel, 20 ms for all channels |
| Resistance Measurement Range | 0 to 400 ohms |
| Operating Temperature Range | -40 °C to 70 °C |
| Storage Temperature Range | -40 °C to 85 °C |
| Humidity Range (Operating and Storage) | 10% RH to 90% RH, 5% RH to 95% RH |
| Vibration (Operating) | 5 grms (Random), 5 g (Sinusoidal), 10 to 500 Hz |
| Weight (Spring Terminal / D-Sub) | 5.7 oz / 5.04 oz |
| Calibration | Available, recommended annually or every two years |