Description
The National Instruments NI-9217 C Series Temperature Input Module, bearing part numbers 192547F-02L and 779592-01, is categorized under C Series Analog Input. This module is specifically designed to cater to a variety of temperature sensing applications, providing a robust solution for engineers and developers.
The NI-9217 model comes equipped with 4 channels, supporting an aggregate sample rate of 400 Samples per second (S/s). It features a comprehensive resistance range from 0 Ω to 400 Ω, making it versatile in its application across different resistance-based measurements.
One of the key aspects of this module is its compatibility with PT100 RTD types, supporting both 3- and 4-wire configurations. This ensures precise temperature measurements and compatibility with a wide range of RTD sensors. Current excitation is provided per channel, enhancing the accuracy of measurements.
Moreover, the NI-9217 ensures high reliability and safety with its channel-to-earth ground double isolation, protecting both the module and connected devices from potential electrical hazards. It is designed for seamless integration with CompactDAQ systems and is also compatible with CompactRIO systems, offering flexibility in system design and deployment.
For developers looking to customize their applications, the module supports programming through various platforms, including NI-DAQmx, LabWindows/CVI, Microsoft Visual C++, and more. This allows for easy integration and development of customized solutions tailored to specific requirements.
The NI-9217 is built to operate under harsh conditions, with an operating temperature range of -40 °C to 70 °C and a storage temperature range of -40 °C to 85 °C. This robust design ensures reliability and performance even in extreme environments.
| Specification | Details |
|---|---|
| Part Number | 192547F-02L, 779592-01 |
| Category | C Series Analog Input |
| Model | NI-9217 |
| Description | National Instruments NI-9217 C Series Temperature Input Module |
| Channels | 4 |
| Aggregate Sample Rate | 400 S/s |
| Resistance Range | 0 Ω to 400 Ω |
| Compatible RTD Types | PT100 |
| RTD Wire Configuration | 3- and 4-wire |
| Current Excitation | Per channel |
| Isolation | Channel-to-earth ground double isolation |
| Interface | CompactDAQ; Compatible with CompactRIO |
| Programming | NI-DAQmx, LabWindows/CVI, Microsoft Visual C++, etc. |
| Operating Temperature Range | -40 °C to 70 °C |
| Storage Temperature Range | -40 °C to 85 °C |
| Operating Humidity Range |