Description
The NI 9219 is a versatile C Series Analog Input module that comes with part numbers 785994-01, 779781-02, and 192496F-01L. It is designed to offer a high level of performance and flexibility for a wide range of applications. The module features 4 channels of analog input, each capable of handling signals up to ±60V and ±25 mA, with a sample rate of 100 S/s per channel. This allows for precise and accurate measurement of various signal types.
One of the key features of the NI 9219 is its 250 Vrms channel-to-channel isolation, which ensures that signals are accurately and safely measured without interference. The module supports a spring terminal connector type, making it easy to connect and disconnect signals as needed. It is built to operate within a wide temperature range of -40 °C to 70 °C, ensuring reliable performance in a variety of environments.
Calibration services are available for the NI 9219, with a recommended calibration period of either annually or every two years to maintain accuracy and performance. This module is compatible with a range of software, including the NI-DAQmx driver; LabVIEW, LabWindows/CVI, C/C++, C#, and Visual Basic .NET, providing flexibility in how it can be integrated and used within different systems.
Additionally, the NI 9219 includes measurement-specific signal conditioning and various isolation options such as bank-to-bank, channel-to-channel, and channel-to-earth ground isolation. These features enhance the module’s ability to provide accurate measurements in complex setups. For further convenience and utility, it can be used with the NI 9972 Backshell Connector Kit, offering a complete solution for high-quality analog input signal measurement.
| Specification | Detail |
|---|---|
| Part Numbers | 785994-01, 779781-02, 192496F-01L |
| Category | C Series Analog Input |
| Model | NI-9219 |
| Description | NI 9219 4 Ch-Ch Isolated, 24-bit, ±60V, 100S/s Universal AI Module |
| Channels | 4 |
| Isolation | 250 Vrms Ch-Ch Isolation |
| Maximum Voltage | ±60 V |
| Maximum Current | ±25 mA |
| Sample Rate | 100 S/s per channel |
| Connector Type | Spring Terminal |
| Operating Temperature Range | -40 °C to 70 °C |
| Calibration | Available, with recommended calibration period of annually or every two years |
| Software Compatibility | NI-DAQmx driver; LabVIEW, LabWindows/CVI, C/C++, C#, Visual Basic .NET |
| Additional Features | Measurement-specific signal conditioning; Isolation options (bank-to-bank, channel-to-channel, channel-to-earth ground); Use with NI 9972 Backshell Connector Kit
Question 1: What is the maximum voltage for the NI 9219? Answer 1: ±60V Question 2: How many channels does the NI 9219 have? Question 3: What is the sample rate per channel on the NI 9219? Question 4: What types of isolation does the NI 9219 support? Question 5: Can the NI 9219 operate in extreme temperatures? |