Description
The NI-9222 with part number 155849A-02L falls under the category of C Series Analog Input. This model is compatible with chassis part numbers 781397-01 and 783283-01. It offers an impressive sampling rate of up to 500 kS/s per channel and features simultaneous ADCs for efficient data conversion.
Designed for versatility, the NI-9222 operates within a temperature range of -40 °C to 70 °C, making it suitable for a wide variety of environments. Additionally, it supports hot swapping and includes a power sleep mode for enhanced energy efficiency.
For software integration, the NI-9222 is compatible with NI-DAQmx driver software. It supports various Application Development Environments (ADEs) including LabVIEW, LabWindows/CVI, C/C++, C#, and Visual Basic .NET. Configuration is made simple through the Measurement & Automation Explorer (MAX) tool.
The screw terminal version of the NI-9222 weighs 4.9 oz, while the BNC model weighs slightly more at 5.8 oz. It has a storage temperature range of -40 °C to 85 °C and can operate and be stored within a humidity range of 10% RH to 90% RH and 5% RH to 95% RH, respectively.
When it comes to durability, the NI-9222 can withstand vibration levels of 5 grms, 5 g (10 Hz to 500 Hz) during operation. For users requiring precise calibration, the device offers NIST accredited calibrations through a third party, ensuring reliable performance and accuracy.
| Specification | Details |
|---|---|
| Part Number | 155849A-02L |
| Category | C Series Analog Input |
| Model | NI-9222 |
| Compatible Chassis Part Numbers | 781397-01, 783283-01 |
| Sampling Rate | Up to 500 kS/s per channel |
| ADCs | Simultaneous |
| Operating Temperature Range | -40 °C to 70 °C |
| Hot Swappable | Yes |
| Power Sleep Mode | Supported |
| Driver Software | NI-DAQmx |
| Compatible ADEs | LabVIEW, LabWindows/CVI, C/C++, C#, Visual Basic .NET |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Screw Terminal Weight | 4.9 oz |
| BNC Model Weight | 5.8 oz |
| Storage Temperature Range | -40 °C to 85 °C |
| Humidity Range (Operating and Storage) | 10% RH to 90% RH, 5% RH to 95% RH |
| Vibration (Operating) | 5 grms, 5 g (10 Hz to 500 Hz) |
| Calibration Available | Yes, NIST accredited calibrations through a 3rd party |
Question 1: What is the sampling rate of NI-9222?
Answer 1: Up to 500 kS/s per channel.
Question 2: Does NI-9222 support hot swapping?
Answer 2: Yes, it supports hot swapping.
Question 3: Can NI-9222 work with LabVIEW?
Answer 3: Yes, it’s compatible with LabVIEW.
Question 4: What is the operating temp range for NI-9222?
Answer 4: -40 °C to 70 °C.
Question 5: Is calibration available for NI-9222?
Answer 5: Yes, NIST accredited calibrations available.