Description
The NI-9222 is a high-performance C Series Analog Input module, distinguished by its part number 783283-01. This module is designed to cater to a wide range of applications requiring precise analog input functionality. It operates with a ±10 V range, offering a 16-Bit resolution to ensure high accuracy in measurements.
One of the key features of the NI-9222 is its impressive sampling rate, capable of reaching up to 500 kS/s per channel. This allows for the capture of high-speed signals without compromising data integrity. Additionally, the module supports simultaneous ADC, enabling all channels to be sampled simultaneously, which is crucial for synchronized data acquisition in many applications.
Designed for versatility, the NI-9222 is compatible with both NI CompactDAQ and CompactRIO systems, with specific part numbers 781397-01 and 783283-01 respectively. This ensures that the module can be integrated seamlessly into existing setups, offering flexibility in system configuration.
The NI-9222 is built to withstand harsh environments, with an operating temperature range of -40 °C to 70 °C and a storage temperature range of -40 °C to 85 °C. It also features a robust humidity range for both operating and storage conditions, from 10% RH to 90% RH and 5% RH to 95% RH respectively. The module’s resilience is further highlighted by its vibration tolerance, withstanding up to 5 grms for random vibration and 5 g from 10 Hz to 500 Hz for sinusoidal vibration.
With a weight of just 5.8 oz for the BNC model, the NI-9222 is lightweight yet durable. Software compatibility is broad, including support for NI-DAQmx, Lab
Specification | Detail |
---|---|
Part Number | 783283-01 |
Category | C Series Analog Input |
Model | NI-9222 |
Description | NI 9222 BNC, +/-10 V, 16-Bit, 500 kS/s, 4-Ch, SS AI Module |
Compatible Chassis | NI CompactDAQ, CompactRIO (Part Numbers: 781397-01, 783283-01) |
Sampling Rate | Up to 500 kS/s per channel |
ADC | Simultaneous |
Operating Temperature Range | -40 °C to 70 °C |
Storage Temperature Range | -40 °C to 85 °C |
Humidity Range (Operating and Storage) | 10% RH to 90% RH, 5% RH to 95% RH respectively |
Vibration (Operating) | Random: 5 grms, Sinusoidal: 5 g (10 Hz to 500 Hz) |
Weight (BNC Model) | 5.8 oz |
Software Compatibility | NI-DAQmx, LabVIEW, LabWindows/CVI, C/C++, C#, Visual Basic