Description
The NI-9223 is a C Series Analog Input module featuring a 4-Channel High Speed SSH Analog Input. This module comes with part numbers 783284-01, 781398-01, and 784535-01. It is designed to handle input voltages in the range of ±10 V and offers a maximum sample rate of 1 MS/s with a resolution of 16-Bit. The NI-9223 supports simultaneous inputs across its four channels, making it highly efficient for various data acquisition tasks.
The module uses four 2-position screw-terminal connectors for signal connection. It incorporates high-speed streaming data technology, ensuring reliable and fast data transfer rates. The NI-9223 is compatible with NIDAQmx driver software, and also supports additional software such as LabVIEW, LabWindows/CVI, and Visual Basic .NET. For verification and testing, it utilizes the Measurement & Automation Explorer (MAX).
Regarding its physical attributes, the screw terminal model of the NI-9223 weighs 4.9 oz, whereas the BNC model is slightly heavier, weighing 5.8 oz. It operates within a temperature range of -40 to 70 °C and can be stored in temperatures ranging from -40 to 85 °C. The operational humidity range is 10 to 90% RH, non-condensing, and the storage humidity range is 5 to 95% RH, non-condensing. Lastly, it can withstand operating vibrations of 5 grms (10 to 500 Hz), demonstrating its robustness in various environmental conditions.
| Specification | Detail |
|---|---|
| Part Numbers | 783284-01, 781398-01, 784535-01 |
| Category | C Series Analog Input |
| Model | NI-9223 |
| Description | 4-Channel High Speed SSH Analog Input |
| Input Voltage Range | ±10 V |
| Maximum Sample Rate | 1 MS/s |
| Resolution | 16-Bit |
| Number of Channels | 4 |
| Signal Input Type | Simultaneous Inputs |
| Connectors | Four 2-position screw-terminal connectors |
| Signal Streaming Technology | Supports high-speed streaming data |
| Driver Software | NIDAQmx |
| Compatible Software | LabVIEW, LabWindows/CVI, Visual Basic .NET |
| Verification Tool | Measurement & Automation Explorer (MAX) |
| Weight (Screw Terminal Model) | 4.9 oz |
| Weight (BNC Model) | 5.8 oz |
| Operating Temperature Range | -40 to 70 °C |
| Storage Temperature Range | -40 to 85 °C |
| Operating Humidity Range | 10 to 90% RH, non-condensing |
| Storage Humidity Range | 5 to 95% RH, non-condensing |
| Operating Vibration (Random) | 5 grms (10 to 500 Hz)
Question 1: What is the voltage range of the NI-9223? Answer 1: ±10 V Question 2: What is the max sample rate of the NI-9223? Question 3: How many channels does the NI-9223 support? Question 4: What type of input does the NI-9223 use? Question 5: What is the operating temperature range of the NI-9223? |