img

198862B-03L

This device offers 3 differential analog input channels with a 24-bit resolution and a max sample rate of 50 kS/s, supporting up to 300 Vrms.

In Stock | Ships Today

img

    Description

    The product comes with Part Numbers 780159-01 and 780159-02, where the latter is conformal coated for additional protection. It is designed to handle an Input Voltage Range of up to 300 Vrms, making it suitable for various applications. The device features 3 differential analog input channels, allowing for versatile data collection and monitoring.

    With a Maximum Sample Rate of 50 kS/s per channel, high-speed data acquisition is achievable, complemented by a Minimum Sample Rate of 1.613 kS/s for slower, more precise measurements. The Operating Voltage Range is specified as 294 Vrms (minimum) to 300 Vrms (typical), ensuring reliable operation under various conditions.

    It boasts Channel-to-Channel Isolation, enhancing the accuracy and reliability of measurements by preventing interference between channels. The device’s Resolution is a high 24-bit analog input, offering excellent precision and detail in the data collected. With a weight of 5.0 oz, it is lightweight and manageable for installation in diverse settings.

    The Recommended Operating Temperature range is -40 to 70 °C, and it can withstand a Storage Temperature Range of -40 to 85 °C, demonstrating its resilience in harsh environmental conditions. In terms of power efficiency, it has a maximum Power Consumption (Active) of 495 mW and goes as low as 25 µW maximum in Sleep mode, optimizing energy use when inactive.

    Calibration services are available, with intervals recommended to be either annual or biennial, ensuring the device remains accurate and reliable over time.

    Specification Detail
    Part Numbers 780159-01, 780159-02
    Conformal Coated Part number 780159-02 only
    Input Voltage Range Up to 300 Vrms
    Channels 3 differential analog input channels
    Maximum Sample Rate 50 kS/s per channel
    Minimum Sample Rate 1.613 kS/s
    Operating Voltage Range 294 Vrms (minimum), 300 Vrms (typical)
    Channel-to-Channel Isolation Yes
    Resolution 24-bit analog input
    Weight 5.0 oz
    Recommended Operating Temperature -40 to 70 °C
    Storage Temperature Range -40 to 85 °C
    Power Consumption (Active) 495 mW maximum
    Power Consumption (Sleep) 25 µW maximum
    Calibration Available, with recommended annual or biennial intervals

    Question 1: What is the input voltage range of the NI-9225?
    Answer 1: Up to 300 Vrms

    Question 2: How many differential analog input channels does it have?
    Answer 2: 3 channels

    Question 3: What is the max sample rate of the NI-9225 per channel?
    Answer 3: 50 kS/s

    Question 4: What is the resolution of the NI-9225’s analog input?
    Answer 4: 24-bit

    Question 5: What is the recommended operating temperature range?
    Answer 5: -40 to 70 °C