Description
The NI-9237 is a part of the C Series Analog Input category, specifically designed for simultaneous strain bridge input. This module stands out with its unique part numbers 780264-01, 779521-01, and 780264-02, catering to diverse needs in the field.
Featuring 4 channels, the NI-9237 provides a high sample rate of 50 kS/s per channel, ensuring accurate and timely data collection. With an impressive 24-bit ADC resolution, this module delivers precise measurements, critical for accurate data analysis and decision-making.
Connectivity is versatile, offering both RJ-50 and DSUB connectors, facilitating easy and flexible integration into various setups. Among the variants, the 780264-02 model is conformal coated, providing additional protection in harsh environments, whereas the other models do not have this feature.
Ensuring safety and reliability, the NI-9237 boasts 60 VDC, 1000 Vrms transient isolation. Its remote sensing capability and shunt calibration feature further enhance its functionality, making it a versatile choice for demanding applications.
Compatibility is broad, with support for NI-DAQmx 8.1 or later, and various programming environments including LabVIEW, LabWindows™/CVI™, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, and Borland C++. This wide range of software compatibility ensures the NI-9237 can easily integrate into existing systems or new developments.
To maintain its high performance and reliability, it is recommended to calibrate the NI-9237 annually or every two years. This ensures the module continues to provide accurate and reliable data, essential for the critical applications it serves.
| Specification | Details |
|---|---|
| Part Numbers | 780264-01, 779521-01, 780264-02 |
| Category | C Series Analog Input |
| Model | NI-9237 |
| Description | Simultaneous Strain Bridge Input Module |
| Channels | 4 |
| Sample Rate | 50 kS/s per channel |
| ADC Resolution | 24 bits |
| Connectivity Options | RJ-50 and DSUB connectors |
| Conformal Coated | 780264-02 (Yes), Others (No) |
| Transient Isolation | 60 VDC, 1000 Vrms |
| Remote Sensing Capability | Yes |
| Shunt Calibration | Yes |
| Software Compatibility | NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, Borland C++ |
| Recommended Calibration Period | Annually or every two years |
Question 1: What is the sample rate of NI-9237 per channel?
Answer 1: 50 kS/s per channel
Question 2: What type of input does NI-9237 specialize in?
Answer 2: Simultaneous strain bridge input
Question 3: What ADC resolution does the NI-9237 have?
Answer 3: 24-bit
Question 4: Does the NI-9237 support remote sensing?
Answer 4: Yes, it has a remote sensing capability
Question 5: What software is compatible with NI-9237?
Answer 5: NI-DAQmx 8.1 or later, LabVIEW, LabWindows/CVI, etc.