Description
The product comes with multiple Part Numbers, specifically 780264-01, 779521-01, and 780264-02, catering to a variety of configurations and needs. It is equipped with 4 Channels, allowing for multiple data inputs simultaneously, enhancing its versatility in various applications.
With a Sample Rate of 50 kS/s/Ch, it ensures precise and timely data collection, making it ideal for high-speed data acquisition tasks. The ADC Resolution is set at 24-Bit, offering high-quality data output, which is critical for detailed analysis and accurate measurements.
The device supports various Connectors, including RJ-50 and DSUB, providing flexibility in connecting different types of sensors and devices. For specific models, notably the 780264-02, the product is Conformal Coated, offering additional protection against environmental factors, enhancing its durability and reliability in harsh conditions.
It boasts an impressive Isolation rating of 60 VDC, with 1000 Vrms transient, ensuring the safety and integrity of data and protecting the device from unexpected power surges. This feature is crucial for applications in electrically noisy environments.
The product is compatible with a wide range of software, including NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, and Borland C++, making it a versatile solution for users with different software preferences and requirements.
For maintenance and optimal performance, an Annual or Biennial Calibration is recommended. This ensures that the device continues to deliver accurate and reliable data over its operational life, adhering to the highest standards of quality and performance.
| Specification | Details |
|---|---|
| Part Numbers | 780264-01, 779521-01, 780264-02 |
| Channels | 4 |
| Sample Rate | 50 kS/s/Ch |
| ADC Resolution | 24-Bit |
| Connectors | RJ-50, DSUB |
| Conformal Coated | Yes (780264-02 only) |
| Isolation | 60 VDC, 1000 Vrms transient |
| Software Compatibility | NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, Borland C++ |
| Calibration Period | Annually or every two years (recommended) |
Question 1: What are the part numbers for NI-9237?
Answer 1: 780264-01, 779521-01, 780264-02
Question 2: How many channels does NI-9237 have?
Answer 2: 4 channels
Question 3: What is the sample rate of NI-9237?
Answer 3: 50 kS/s/Ch
Question 4: What ADC resolution does NI-9237 offer?
Answer 4: 24-Bit
Question 5: What type of calibration is recommended for NI-9237?
Answer 5: Annual or Biennial Calibration