img

198855B-01L

This device features 4 channels, 50 kS/s per channel, 24-bit ADC, RJ-50 and DSUB connectivity, and supports NI-DAQmx 8.1 or later software.

In Stock | Ships Today

img

    Description

    The product specifications are detailed and cater to a wide range of applications. The part numbers associated with this product are 780264-01, 779521-01, and 780264-02. The device boasts 4 channels, allowing for multitasking and efficient data handling.

    It offers a sample rate of 50 kS/s per channel, providing accurate and timely data acquisition. The ADC resolution stands at 24 bits, ensuring high precision in measurements.

    For connectivity, users have the options of RJ-50 and DSUB, allowing for versatile and reliable connections to other devices. An important feature of this product is its conformal coated option, available with part number 780264-02, which enhances durability and protection.

    The device also offers isolation up to 60 VDC, with a 1000 Vrms transient, ensuring safety and reliability in various operating conditions. Additionally, remote sensing capability is included, enhancing its functionality and usability in different environments.

    Shunt calibration is another valuable feature, providing ease of use and accuracy in measurements. Regarding software compatibility, this product works seamlessly with NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, and Borland C++, ensuring broad compatibility and integration with existing systems.

    The recommended calibration period is annually or every two years, depending on usage, ensuring long-term reliability and accuracy in measurements.

    Specification Detail
    Part Numbers 780264-01, 779521-01, 780264-02
    Channels 4
    Sample Rate 50 kS/s Per Channel
    ADC Resolution 24 bits
    Connectivity Options RJ-50, DSUB
    Conformal Coated Option Yes (Part Number: 780264-02)
    Isolation 60 VDC, 1000 Vrms Transient
    Remote Sensing Capability Yes
    Shunt Calibration Yes
    Software Compatibility NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, Borland C++
    Recommended Calibration Period Annually or every two years

    Question 1: How many channels does the NI-9237 have?
    Answer 1: 4 channels

    Question 2: What is the sample rate per channel for the NI-9237?
    Answer 2: 50 kS/s

    Question 3: What ADC resolution does the NI-9237 offer?
    Answer 3: 24 bits

    Question 4: What types of connectivity does the NI-9237 support?
    Answer 4: RJ-50 and DSUB

    Question 5: What software is the NI-9237 compatible with?
    Answer 5: NI-DAQmx 8.1 or later and more