Description
The product with part numbers 781098-01 and 781098-02 is designed to deliver high performance in various applications. It features a 16-bit bit depth, ensuring precise data representation. With 4 Analog Output channels, it provides ample connectivity for multiple sensors or devices.
It offers a maximum sampling rate of 100 kS/s per channel, enabling fast data acquisition and processing. The device ensures channel-to-channel isolation, enhancing the accuracy and reliability of measurements by preventing signal interference between channels.
The voltage output range is ±10 V, allowing for a wide range of signal generation capabilities. Each channel can drive currents up to ±10 mA maximum, with a total output current capability of ±20 mA. This ensures sufficient power for a variety of applications without compromising performance.
With a weight of 5.5 oz., the device is lightweight and portable, making it suitable for both lab and field applications. It is designed to operate within a wide temperature range of -40 °C to 70 °C, ensuring reliability under extreme conditions.
Calibration is available, with a recommendation for it to be performed annually or biennially to maintain accuracy and performance. Software support includes the LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, and LabVIEW Real-Time Module, providing a comprehensive development environment for various applications.
Additional features include support for NI CompactDAQ (as of NI-DAQmx Version 9.1). It is important to note that it is not feasible to link output channels in parallel to enhance current drive, ensuring users are aware of the device’s limitations and capabilities.
| Specification | Detail |
|---|---|
| Part Numbers | 781098-01, 781098-02 |
| Bit Depth | 16-bit |
| Channels | 4 Analog Output |
| Maximum Sampling Rate | 100 kS/s per channel |
| Channel-to-Channel Isolation | Yes |
| Voltage Output Range | ±10 V |
| Current Drive (per channel) | ±10 mA maximum |
| Total Output Current | ±20 mA |
| Weight | 5.5 oz. |
| Recommended Operating Temperature | -40 °C to 70 °C |
| Calibration | Available, Recommended Annually or Biennially |
| Software Support | LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, LabVIEW Real-Time Module |
| Additional Features | NI CompactDAQ support (as of NI-DAQmx Version 9.1), Not feasible to link output channels in parallel to enhance current drive |
Question 1: What bit depth does the NI-9269 offer?
Answer 1: 16-bit
Question 2: How many analog output channels does the NI-9269 have?
Answer 2: 4 channels
Question 3: What is the max sampling rate per channel for the NI-9269?
Answer 3: 100 kS/s
Question 4: What voltage output range does the NI-9269 support?
Answer 4: ±10 V
Question 5: Is calibration available for the NI-9269?
Answer 5: Yes, annually or biennially.