img

198920A-01L

This device features part numbers 781098-01, 781098-02, 16-bit resolution, 4 analog output channels, and supports LabVIEW software.

In Stock | Ships Today

img

    Description

    The product comes with Part Numbers 781098-01 and 781098-02, ensuring a variety of choices for specific needs. It boasts a high Resolution of 16-bit, providing precise output for demanding applications. With 4 analog output channels, it offers flexibility in data management and signal processing.

    Designed for high-speed performance, it has a Maximum Sampling Rate of 100 kS/s per channel, ensuring efficient data acquisition and processing. It also features Channel-to-Channel Isolation, enhancing signal integrity and reducing noise interference among channels.

    The Output Voltage Range is versatile at ±10 V, suitable for a wide range of applications. Its Current Drive Capability is robust, with ±10 mA maximum per channel and ±20 mA total for all channels, ensuring sufficient power for output devices.

    Compatibility with leading software is guaranteed as it supports LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, and LabVIEW Real-Time Module. Additionally, it offers seamless integration with NI CompactDAQ systems as of NI-DAQmx Version 9.1, expanding its utility and application range.

    Operational efficiency is maintained across a wide temperature range, from -40 °C to 70 °C, making it suitable for harsh environments. Despite its robust features, it remains lightweight at 5.5 oz., enhancing its portability and ease of installation.

    Maintenance and accuracy are straightforward with two Calibration Options: NIST accredited calibrations through a 3rd party and basic (unaccredited) in-house calibration. To ensure optimal performance, a Recommended Calibration Period of annually or every two years is advised.

    Specification Detail
    Part Numbers 781098-01, 781098-02
    Resolution 16-bit
    Number of Channels 4 analog output channels
    Maximum Sampling Rate 100 kS/s per channel
    Channel-to-Channel Isolation Yes
    Output Voltage Range ±10 V
    Current Drive Capability ±10 mA maximum per channel, ±20 mA total for all channels
    Supporting Software LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, LabVIEW Real-Time Module
    NI CompactDAQ Support Yes, as of NI-DAQmx Version 9.1
    Recommended Operating Temperature -40 °C to 70 °C
    Weight 5.5 oz.
    Calibration Options NIST accredited calibrations through a 3rd party, basic (unaccredited) in-house calibration
    Recommended Calibration Period Annually or every two years

    Question 1: What is the resolution of the NI-9269?
    Answer 1: 16-bit

    Question 2: How many analog output channels does the NI-9269 have?
    Answer 2: 4 channels

    Question 3: What software does the NI-9269 support?
    Answer 3: LabVIEW software

    Question 4: What is the maximum sampling rate of the NI-9269?
    Answer 4: 100 kS/s per channel

    Question 5: What are the calibration options for the NI-9269?
    Answer 5: NIST accredited and in-house