The NI-9269 model, identified by part numbers 781098-01 and 781098-02, is a high-performance module that features a 16-bit resolution to ensure precise data measurement and conversion. It is equipped with 4 analog output channels, each capable of a maximum sampling rate of 100 kS/s (kilo-samples per second) per channel, allowing for fast and efficient data output.
One of the key features of the NI-9269 is its channel-to-channel isolation, which enhances the accuracy and reliability of measurements by minimizing electrical interference between channels. The module offers an output voltage range of ±10 V, providing flexibility across various signal ranges. Additionally, it is capable of delivering a maximum output current of ±10 mA per channel, with a cumulative total of ±20 mA across all channels, ensuring sufficient power for a wide range of applications.
The NI-9269 is supported by several pieces of software, including the LabVIEW Professional Development System, LabVIEW FPGA Module, and LabVIEW Real-Time Module. These software tools offer comprehensive support for developing applications that require real-time data processing and control. Furthermore, the module is compatible with NI CompactDAQ systems as of NI-DAQmx Version 9.1, providing seamless integration with other NI hardware.
Designed for durability and reliability, the NI-9269 operates optimally within a recommended operating temperature range of -40 °C to 70 °C. It has a lightweight design, weighing in at 5.5 oz., making it suitable for various deployment scenarios. For users seeking to maintain the module’s high performance, calibration is available through Apex Waves with NIST accredited calibrations. It is recommended that the module be calibrated annually or every two years to ensure continued accuracy and reliability.
| Specification | Detail |
|---|---|
| Part Numbers | 781098-01, 781098-02 |
| Model | NI-9269 |
| Resolution | 16-bit |
| Number of Channels | 4 analog output channels |
| Maximum Sampling Rate | 100 kS/s per channel |
| Channel-to-Channel Isolation | Yes |
| Output Voltage Range | ±10 V |
| Maximum Output Current | ±10 mA per channel, ±20 mA total |
| Supporting Software | LabVIEW Professional Development System, LabVIEW FPGA Module, LabVIEW Real-Time Module |
| NI CompactDAQ Support | Yes, as of NI-DAQmx Version 9.1 |
| Recommended Operating Temperature | -40 °C to 70 °C |
| Weight | 5.5 oz. |
| Calibration Available | Yes, through Apex Waves with NIST accredited calibrations |
| Recommended Calibration Period | Annually or every two years |
Question 1: What is the resolution of the NI-9269?
Answer 1: 16-bit resolution
Question 2: How many analog output channels does the NI-9269 have?
Answer 2: 4 channels
Question 3: What is the max sampling rate per channel for NI-9269?
Answer 3: 100 kS/s
Question 4: What software supports the NI-9269?
Answer 4: LabVIEW Professional, FPGA, Real-Time Modules
Question 5: What is the recommended operating temperature for NI-9269?
Answer 5: -40 °C to 70 °C