Description
The product features a variety of Part Numbers including 783730-01, 779013-01, 779372-01, and 189880-51, catering to diverse needs and setups.
It boasts 8 single-ended Input Channels, providing versatility in measurements. The Input Range is quite flexible at ±10 V, accommodating a wide spectrum of signal levels.
The device incorporates a 12-Bit, Successive approximation register (SAR) ADC Type, ensuring precise data conversion. With a Maximum Sampling Rate of 500 kS/s, it is capable of capturing rapid signal changes efficiently.
Overvoltage Protection is robust at ±100 V (channel-to-COM), safeguarding the device against unexpected voltage spikes. The Gain Error and Offset Error are remarkably low at ±0.04% and ±0.07% respectively, ensuring accuracy in measurements.
The device’s performance is reliable over temperature variations, with a Gain Drift of ±34 ppm/°C and an Offset Drift of ±100 µV/°C. Power Consumption is optimized at 1 W during active mode and drops significantly to 1 mW in sleep mode, making it energy efficient.
It supports multiple Terminal Types including Screw terminal (779013-01), Spring terminal (783730-01), and DSUB connector (779372-01), offering flexibility in connectivity. The Measurement Category is Category II, with a Voltage Capability of up to 250 Vrms constant and 2,300 Vrms surge, ensuring safe operation in various electrical environments.
The device boasts an impressive MTBF (Mean Time Between Failures) of 1,092,512 hours, highlighting its reliability and durability. It is compatible with a range of software including NI-DAQmx, LabVIEW, LabWindows/CVI, C/C++, C#, and Visual Basic .NET, making it versatile for different programming needs.
Its Weight varies
| Feature | Description |
|---|---|
| Part Numbers | 783730-01, 779013-01, 779372-01, 189880-51 |
| Input Channels | 8 single-ended |
| Input Range | ±10 V |
| ADC Type | 12-Bit, Successive approximation register (SAR) |
| Maximum Sampling Rate | 500 kS/s |
| Overvoltage Protection | ±100 V (channel-to-COM) |
| Gain Error | ±0.04% |
| Offset Error | ±0.07% |
| Gain Drift | ±34 ppm/°C |
| Offset Drift | ±100 µV/°C |
| Power Consumption (Active/Sleep) | 1 W / 1 mW |
| Terminal Types | Screw terminal (779013-01), Spring terminal (783730-01), DSUB connector (779372-01) |
| Measurement Category | Category II |
| Voltage Capability | Up to 250 Vrms constant, 2,300 Vrms surge |
| MTBF | 1,092,512 hours |
| Software Compatibility | NI-DAQmx, LabVIEW, LabWindows/CVI, C/C++, C#, Visual Basic .NET |
| Weight (Screw/Spring/DSUB) | 5.8 oz / 5.4 oz / 5.0 oz |
| Operating Temperature Range | -40 °C to 70 °C |
| Calibration