img

192607H-71L

This device features 8 single-ended input channels with a ±10 V range, 12-Bit resolution, and a 500 kS/s max sampling rate, supported by NI-DAQmx and LabVIEW.

In Stock | Ships Today

img

    Description

    The product comes with various Part Numbers including 783730-01, 779013-01, 779372-01, and 189880-51, catering to a wide range of applications and needs.

    It features 8 single-ended Input Channels which allow for versatile data collection from multiple sources simultaneously. The Input Range of ±10 V is designed to accommodate a variety of signal strengths, ensuring accurate data capture.

    With a Resolution of 12-Bit, this product provides precise measurement, capturing the nuances of the input signal. The Maximum Sampling Rate of 500 kS/s ensures that even rapidly changing signals are accurately represented in the data.

    It offers Overvoltage Protection up to ±100 V, safeguarding the device against unexpected power surges. The ADC Type utilized is the Successive approximation register (SAR), known for its reliability and accuracy.

    Power efficiency is optimized with a Power Consumption of 1 W in Active Mode and only 1 mW in Sleep Mode, making it an eco-friendly choice. The Gain Error and Offset Error are exceptionally low at ±0.04% and ±0.07% respectively, ensuring high fidelity in measurements.

    Temperature stability is guaranteed with a Gain Drift of ±34 ppm/°C and an Offset Drift of ±100 µV/°C. It is classified under Measurement Category II for heightened safety. The MTBF (Mean Time Between Failures) is impressively high at 1,092,512 hours, indicating a reliable long-term performance.

    For software integration, it is compatible with NI-DAQmx, LabVIEW, ensuring ease of use and flexibility in data management and analysis.

    Specification Description
    Part Numbers 783730-01, 779013-01, 779372-01, 189880-51
    Input Channels 8 single-ended
    Input Range ±10 V
    Resolution 12-Bit
    Maximum Sampling Rate 500 kS/s
    Overvoltage Protection Up to ±100 V
    ADC Type Successive approximation register (SAR)
    Power Consumption (Active Mode) 1 W
    Power Consumption (Sleep Mode) 1 mW
    Gain Error ±0.04%
    Offset Error ±0.07%
    Gain Drift ±34 ppm/°C
    Offset Drift ±100 µV/°C
    Measurement Category II
    MTBF 1,092,512 hours
    Compatible Software NI-DAQmx, LabVIEW,

    Question 1: What is the maximum input range of the NI-9201?
    Answer 1: ±10 V

    Question 2: What resolution does the NI-9201 offer?
    Answer 2: 12-Bit

    Question 3: How many input channels does the NI-9201 have?
    Answer 3: 8 single-ended

    Question 4: What is the NI-9201’s max sampling rate?
    Answer 4: 500 kS/s

    Question 5: What software is the NI-9201 compatible with?
    Answer 5: NI-DAQmx, LabVIEW