img

192346F-01L

The PCI-4462 is a 24-bit, 4-channel differential analog input card with up to 204.8 kS/s sampling, software-programmable attenuation, and BNC/SMB connectors.

In Stock | Ships Today

img

    Description

    The product with part number 779309-01 is a high-precision data acquisition device, model PCI-4462. This particular model is equipped with 4 differential analog input channels, allowing for detailed and accurate data collection. The 24-bit Analog-to-Digital Converter (ADC) resolution ensures high fidelity in signal conversion, matching the resolution available for output channels as well.

    It is capable of reaching a maximum sample rate of 204.8 kS/s, providing ample bandwidth for a variety of data acquisition needs. Users can adjust the signal input strength through software-programmable attenuation settings of 0, 20, or 40 dB, allowing for flexibility in signal acquisition without compromising the signal quality, as evidenced by its frequency response evenness of ±0.1 dB.

    Connectivity options include BNC female analog I/O and SMB male digital trigger connectors, facilitating easy integration into existing setups. The device interfaces with both 3.3 V and 5 V PCI bus interfaces, ensuring compatibility with a wide range of computer systems. It supports 1 analog input DMA channel, streamlining data transfer processes.

    Before reaching optimal performance, the PCI-4462 requires a warm-up time of 15 minutes. Calibration is crucial for maintaining accuracy; thus, it supports both self-calibration and external calibration, with a recommended calibration interval of every 1 year.

    The device is relatively lightweight at 8.0 oz and has compact dimensions of 6.9 x 3.9 inches, making it easy to incorporate into a variety of setups without requiring excessive space. It operates within a temperature range of 0 to 55 °C, ensuring reliability under varied environmental conditions. For storage, it is designed to withstand temperatures from -20 to 70 °C, guaranteeing durability and longevity of the device even when not in use.

    Specification Details
    Part Number 779309-01
    Model PCI-4462
    Input Channels 4 differential analog
    ADC Resolution 24-bit
    Output Channels Resolution 24-bit
    Maximum Sample Rate 204.8 kS/s
    Software-Programmable Attenuation 0, 20, or 40 dB
    Frequency Response Evenness ±0.1 dB
    Connectors BNC female analog I/O, SMB male digital trigger
    PCI Bus Interface 3.3 V or 5 V
    DMA Channels 1 analog input
    Warm-Up Time 15 minutes
    Calibration Self-calibration, external calibration available
    Recommended Calibration Interval 1 year
    Weight 8.0 oz.
    Dimensions 6.9 x 3.9 in.
    Operating Temperature Range 0 to 55 °C
    Storage Temperature -20 to 70 °C

    Question 1: What is the ADC resolution of the PCI-4462?
    Answer 1: 24-bit.

    Question 2: How many analog input channels does the PCI-4462 have?
    Answer 2: 4 differential channels.

    Question 3: What is the maximum sample rate of the PCI-4462?
    Answer 3: 204.8 kS/s.

    Question 4: What types of connectors does the PCI-4462 use?
    Answer 4: BNC female and SMB male.

    Question 5: What is the warm-up time required for the PCI-4462?
    Answer 5: 15 minutes.