The NI PCI-4070 is identified by its part number 778275-01 and stands as a notable model in the realm of digital multimeters. This device, described as the NI PCI-4070 6 ½ Digit FlexDMM, offers a comprehensive range of features tailored for precise measurements and broad compatibility.
One of the key highlights of this device is its digitizer rate, which reaches up to 1.8 MS/s, ensuring rapid data acquisition for various applications. The voltage range supported by the PCI-4070 extends up to 300 V, while the current range accommodates up to 1 A, making it versatile for numerous electrical testing scenarios.
The device boasts an impressive basic DC voltage accuracy of 25 ppm, ensuring reliable and precise readings. Compatibility is a strong suit of the PCI-4070, as it supports NI-DMM driver software (version 3.0.2 or later), along with integration capabilities with LabVIEW, LabWindows/CVI, Microsoft Visual C++, and Microsoft Visual Basic, providing flexibility in programming and data analysis.
Equipped with 12 built-in measurement functions, the PCI-4070 can perform a wide range of tasks, further enhanced by its self-calibration feature for accuracy maintenance. It also features an isolated digitizer mode for measuring both AC and DC-coupled waveforms, adding to its versatility.
Users can select from multiple resolution options in DC mode, including 7, 6.5, 5.5, 4.5, and 3 digits, allowing for flexibility in precision based on the requirements of the task at hand. The device operates within a temperature range of 0 °C to 40 °C, accommodating various environmental conditions.
Finally, the PCI-4070 supports a maximum sampling rate that varies from 5 S per second to 1.8 MS/sec, alongside a robust maximum trigger rate
| Specification | Detail |
|---|---|
| Part Number | 778275-01 |
| Model | PCI-4070 |
| Description | NI PCI-4070 6 ½ Digit FlexDMM |
| Digitizer Rate | 1.8 MS/s |
| Voltage Range | 300 V |
| Current Range | 1 A |
| Basic DC Voltage Accuracy | 25 ppm |
| Software Compatibility | NI-DMM driver software (version 3.0.2 or later), LabVIEW, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic |
| Measurement Functions | 12 built-in measurement functions |
| Self-Calibration | Yes |
| Isolated Digitizer Mode | AC and DC-coupled waveforms measurement |
| Resolution Options in DC Mode | 7, 6.5, 5.5, 4.5, 3 digits |
| Operating Temperature Range | 0 °C to 40 °C |
| Maximum Sampling Rate | 5 S per second to 1.8 MS/sec |
| Maximum Trigger Rate in
Question 1: What is the digitizer rate of the NI PCI-4070? Question 2: What voltage range does the PCI-4070 support? Question 3: What is the basic DC voltage accuracy of the PCI-4070? Question 4: Can the PCI-4070 perform self-calibration? Question 5: What is the maximum trigger rate of the PCI-4070? |