The PCI-4474 model falls under the category of PC-based DSA and comes with part numbers 778729-01, 778778-01, 189545A-01. This device offers a high-resolution data acquisition system with a 24 Bit resolution, ensuring precise and accurate data capture. With a maximum sampling rate of 102.4 kS/s, it can efficiently process data at high speeds.
This model is equipped with 4 inputs, providing flexibility in connecting multiple sensors simultaneously. It boasts a dynamic range of more than 110 dB, allowing it to accurately capture both high and low amplitude signals without distortion. The input coupling is software-selectable AC/DC, adding to the device’s versatility in handling different types of signals.
It features a high pass filter with a cutoff frequency of 3.4 Hz to eliminate low-frequency noise and improve signal quality. The connectors used are SMB front connectors, which offer a reliable and secure connection for data acquisition.
The warm-up time for this device is 15 minutes, ensuring it is ready to deliver accurate measurements after a short period. For calibration, it is self-calibrated on software command, with an external calibration recommended annually to maintain its accuracy and reliability.
The PCI-4474 is compatible with various software, including NI-DAQmx, LabVIEW, LabWindows/CVI, and Measurement Studio, making it a flexible solution for a wide range of data acquisition tasks. With a weight of 6.5 oz. and dimensions of 6.9 x 4.2 in., this device is compact and easy to integrate into various setups. Lastly, its operating temperature range is suitable for a variety of environments, ensuring reliable performance under different conditions.
“`
| Specification | Details |
|---|---|
| Part Numbers | 778729-01, 778778-01, 189545A-01 |
| Model | PCI-4474 |
| Category | PC-based DSA |
| Resolution | 24 Bit |
| Maximum Sampling Rate | 102.4 kS/s |
| Number of Inputs | 4 Inputs |
| Dynamic Range | > 110 dB |
| Coupling | Software-selectable AC/DC |
| High Pass Filter Cutoff Frequency | 3.4 Hz |
| Connectors | SMB front connectors |
| Warm-up Time | 15 minutes |
| Calibration | Self-calibrated on software command, External calibration recommended annually |
| Software Compatibility | NI-DAQmx, LabVIEW, LabWindows/CVI, Measurement Studio |
| Weight | 6.5 oz. |
| Dimensions | 6.9 x 4.2 in. |
| Operating Temperature Range | 0 to
Question 1: What is the max sampling rate of the PCI-4474? Question 2: What type of connectors does the PCI-4474 use? Question 3: How long is the warm-up time for the PCI-4474? Question 4: What is the recommended calibration interval for the PCI-4474? Question 5: Is the input coupling of the PCI-4474 software-selectable? |