Description
The PCI-5102 is a PC-based oscilloscope/digitizer that offers a comprehensive set of capabilities for capturing and analyzing electronic signals. With a Part Number of 777304-01, this model is designed to fit seamlessly into a variety of measurement and testing setups.
This oscilloscope/digitizer features 2 channels, allowing for the simultaneous measurement of two signals. It boasts a sampling rate of 20 MS/s, which can be effectively increased up to 1 GS/s with Random Interleaved Sampling (RIS), ensuring high-resolution capture of signal nuances over time.
The analog input bandwidth of 15 MHz supports a wide range of frequencies, making the PCI-5102 suitable for numerous applications. Users can work within an input voltage range of ±50 mV to ±5 Volts, which can be extended up to ±50 V with the use of attenuating probes, offering flexibility in handling various signal amplitudes.
AC/DC coupling is software-selectable, providing users with the versatility to measure signals as per requirement. The oscilloscope/digitizer captures data with an 8-bit resolution, ensuring detailed signal representation. It also includes onboard memory capable of storing approximately 663,000 samples, allowing for extended data collection sessions.
Supported by NI-DMM driver software, the PCI-5102 facilitates easy integration with existing systems and simplifies the setup process. It offers multiple sophisticated triggering options, including hysteresis values, programmable thresholds, bi-level triggering, and trigger hold off, providing users with the flexibility to capture signals based on specific conditions. Additionally, the device includes two TTL/CMOS digital triggers, further enhancing its utility in complex measurement setups.
The physical dimensions of the PCI-5102 are 4.2 x 6.87 inches, making it a compact addition to any workspace.
| Specification | Detail |
|---|---|
| Part Number | 777304-01 |
| Category | PC-based Oscilloscopes/Digitizers |
| Model | PCI-5102 |
| Channels | 2 |
| Sampling Rate | 20 MS/s |
| Effective Sampling Rate (with RIS) | Up to 1 GS/s |
| Analog Input Bandwidth | 15 MHz |
| Input Voltage Range | ±50 mV to ±5 Volts (extendable up to ±50 V with attenuating probes) |
| AC/DC Coupling | Software-selectable |
| Resolution | 8-bit |
| Onboard Memory | Approx. 663,000 samples |
| Driver Software | NI-DMM |
| Triggering Options | Multiple sophisticated options including hysteresis values, programmable thresholds, bi-level triggering, trigger hold off |
| Digital Triggers | Two TTL/CMOS |
| Physical Dimensions | 4.2 x 6.87 in. |