Description
The PCI-5411 is a PC-based Arbitrary Waveform Generator, with the part number 183962G-01, that operates on the principle of DDS (Direct Digital Synthesis). It supports RTSI (Real-Time System Integration) for enhanced synchronization capabilities, specifically through external clocks via Phase-Locked Loop (PLL) technology. This device stands out for its waveform linking and looping features, making it highly versatile for various applications.
It has a single analog output channel that is 12-bit, DC-coupled, providing a precise and reliable signal output. The maximum frequency achievable is 16 MHz for TTL signals, and for square, ramp, and triangle waveforms, it can go up to 1 MHz. The frequency resolution in DDS mode is remarkably high at 9.31 MHz, backed by a 32-bit DDS accumulator resolution, ensuring fine granularity in waveform generation.
The sampling rate of the PCI-5411 can reach up to 40 MS/sec, allowing for high-speed data processing and signal generation. It offers flexible output impedance options, including 50 Ω nominal or 75 Ω high impedance, to match various system requirements. Depending on the chosen impedance, the voltage output can be either +5V or +10V, providing flexibility for different power needs.
In summary, the PCI-5411 is an advanced PC-based Arbitrary Waveform Generator designed for precise and flexible signal generation, making it an ideal choice for engineers and researchers in need of high-performance waveform generation tools.
| Specification | Detail |
|---|---|
| Part Number | 183962G-01 |
| Category | PC-based Arbitrary Waveform Generators |
| Model | PCI-5411 |
| Principle of Operation | DDS (Direct Digital Synthesis) |
| Supports RTSI | Yes |
| Synchronization | External clocks through PLL |
| Features | Waveform linking and looping |
| Analog Output Channels | 1 (12-bit, DC-coupled) |
| Maximum Frequency (TTL) | 16 MHz |
| Maximum Frequency (Square, Ramp, Triangle) | 1 MHz |
| Frequency Resolution (DDS Mode) | 9.31 MHz |
| DDS Accumulator Resolution | 32 bits |
| Sampling Rate | Up to 40 MS/sec |
| Output Impedance Options | 50 Ω nominal or 75 Ω high impedance |
| Voltage Output | +5V or +10V (depending on impedance) |
| Waveform Generation |
Question 1: What is the part number for the PCI-5411? Question 2: What maximum frequency can the PCI-5411 achieve for TTL signals? Question 3: How many analog output channels does the PCI-5411 have? Question 4: What is the maximum sampling rate of the PCI-5411? Question 5: Does the PCI-5411 support Real-Time System Integration (RTSI)? |