img

187576D-01

The PCI-6034E by National Instruments is a PC-based Multifunction DAQ from the E Series, featuring 16/8 analog channels, 16 bits resolution, and 200 kS/s max sampling rate.

In Stock | Ships Today

img

    Description

    The PCI-6034E is a PC-based Multifunction DAQ device, part of the E Series, and manufactured by National Instruments. The part number for this device is 187576D-01 (778075-01). It is designed to provide a flexible and powerful solution for a wide range of data acquisition applications.

    The device boasts 16 single-ended or 8 differential analog input channels, offering users the versatility needed for various measurement requirements. With a 16-bit resolution and a maximum sampling rate of 200 kS/s, it ensures high-quality data capture and processing. The input voltage range is specified as ±11 V of ground, providing a broad range for different signal types.

    Regarding analog input signals, the PCI-6034E supports ACH<0..15>, ASENSE, AIGND, allowing for comprehensive monitoring and measurement capabilities. Additionally, the device comes equipped with 8 digital I/O lines and Programmable Function Inputs (PFI) located on the I/O connector. Speaking of connectors, this DAQ device utilizes a 68-pin male SCSI-II type connector, ensuring secure and reliable physical connections.

    For optimal performance, it is recommended to allow a warm-up time of 15 minutes before using the device. Furthermore, to maintain accuracy and reliability, calibration is advised once a year. The PCI-6034E is quite lightweight, weighing in at only 5.3 oz, making it an easy addition to any setup without adding significant bulk.

    < Question 1: What is the max sampling rate of the PCI-6034E?
    Answer 1: 200 kS/s

    Question 2: How many analog input channels does PCI-6034E have?
    Answer 2: 16 single-ended or 8 differential

    Question 3: What is the resolution of the PCI-6034E?
    Answer 3: 16 bits

    Question 4: What type of connector does the PCI-6034E use?
    Answer 4: 68-pin male SCSI-II type

    Question 5: What is the recommended calibration frequency for the PCI-6034E?
    Answer 5: Once a year

    Specification Detail
    Part Number 187576D-01 (778075-01)
    Category PC-based Multifunction DAQ
    Model PCI-6034E
    Manufacturer National Instruments
    Series E Series
    Analog Input Channels 16 single-ended or 8 differential
    Resolution 16 bits
    Max Sampling Rate 200 kS/s
    Input Voltage Range ±11 V of ground
    Analog Input Signals ACH<0..15>, ASENSE, AIGND
    Digital I/O Lines 8
    Programmable Function Inputs (PFI) On I/O connector
    I/O Connector 68-pin male SCSI-II type
    Recommended Warm-up Time 15 minutes
    Calibration Once a year
    Weight 5.3 oz