img

184111N-01

The National Instruments PCI-6110 is a PC-based DAQ with 4 differential analog inputs, 2 outputs, and 8 digital channels, supporting parallel sampling.

In Stock | Ships Today

img

    Description

    The PCI-6110 is a PC-based multifunction DAQ produced by National Instruments, bearing the part number 777475-01. This device is designed for a wide range of applications, offering 4 differential analog input channels with an input range of 20 V (from -10 V to +10 V).

    It boasts a 12-bit resolution for analog inputs, ensuring precise data acquisition, and supports a maximum sampling rate of 5 MS/s, allowing for high-speed data capture. The analog input accuracy of the PCI-6110 is specified at 252 mV, highlighting its reliability in capturing accurate data.

    Furthermore, the device includes 2 analog output channels with a 16-bit output resolution, capable of reaching a sampling rate of up to 4 MS/s. This feature enables it to deliver output signals with high fidelity. Additionally, it is equipped with 8 digital channels that are 5 V/TTL compatible, enhancing its versatility for various digital interfacing requirements.

    One of the notable features of the PCI-6110 is its support for parallel sampling, allowing simultaneous sampling across multiple channels. For connectivity, it utilizes a 68-pin male SCSI II type I/O connector, ensuring robust and reliable physical connections. The device is also supported by the NI-DAQ driver, offering seamless integration with software for data acquisition and analysis.

    The PCI-6110 includes a FIFO buffer of 8192 samples, significantly reducing the risk of data overflow and ensuring smooth data transfer during high-speed acquisition sessions. This technical specification makes the PCI-6110 an efficient and reliable choice for a wide range of data acquisition tasks.

    Question 1: What is the input voltage range of the PCI-6110?
    Answer 1: -10 V to +10 V

    Question 2: What is the analog input resolution of the PCI-6110?
    Answer 2: 12-bit

    Question 3: What is the maximum sampling rate of the PCI-6110?
    Answer 3: 5 MS/s

    Question 4: How many analog output channels does PCI-6110 have?
    Answer 4: 2 channels

    Question 5: What type of connector does the PCI-6110 use?
    Answer 5: 68-pin male SCSI II type

    Specification Detail
    Part Number 777475-01
    Category PC-based Multifunction DAQ
    Model PCI-6110
    Manufacturer National Instruments
    Analog Input Channels 4 differential
    Input Range 20 V (from -10 V to +10 V)
    Resolution 12-bit
    Sampling Rate 5 MS/s
    Analog Input Accuracy 252 mV
    Analog Output Channels 2
    Output Resolution 16-bit
    Output Sampling Rate 4 MS/s
    Digital Channels 8 (5 V/TTL compatible)
    Parallel Sampling Supported
    I/O Connector 68-pin male SCSI II type
    Software Support NI-DAQ driver
    FIFO Buffer 8192 samples