Description
The product with Part Number 779110-01 falls under the category of PC-based Multifunction DAQ, specifically the model PCI-6284. This device boasts an impressive 32 Analog Inputs and 48 Digital I/O, making it incredibly versatile for a wide range of data acquisition tasks.
When it comes to analog trigger modes, the PCI-6284 offers Analog window triggering, Analog edge triggering with hysteresis, and Analog edge triggering. These features provide users with flexible options for capturing data, ensuring precise control over the triggering process. Furthermore, the device has an Analog Trigger Resolution of 10 bits and an Analog Trigger Accuracy of ±1%, indicating its ability to perform with high precision.
The PCI-6284 is equipped with 2 General Purpose counters/timers that have a 32-bit resolution. This functionality enhances its capability to handle complex timing tasks. The Base Clock Precision is rated at 50 ppm, showcasing the device’s ability to maintain accuracy over time. It supports an Internal Base Clock Frequency of 0.1 MHz, 20 MHz, and 80 MHz, along with an External Base Clock Frequency Range from 0 MHz to 20 MHz. This wide range of frequencies allows for great flexibility in timing and synchronization tasks.
Compliance with Electrical gear protection and EMC standards ensures that the PCI-6284 meets safety and electromagnetic compatibility requirements, making it suitable for a variety of industrial environments. The Maintenance Phase Start Date for this device is March 31, 2022, indicating the commitment to long-term support and reliability.
| Specification | Detail |
|---|---|
| Part Number | 779110-01 |
| Category | PC-based Multifunction DAQ |
| Model | PCI-6284 |
| Analog Inputs | 32 |
| Digital I/O | 48 |
| Analog Trigger Modes | Analog window triggering, Analog edge triggering with hysteresis, Analog edge triggering |
| Analog Trigger Resolution | 10 bits |
| Analog Trigger Accuracy | ±1% |
| Counter/Timers | 2 General Purpose with 32-bit resolution |
| Base Clock Precision | 50 ppm |
| Internal Base Clock Frequency | 0.1 MHz, 20 MHz, 80 MHz |
| External Base Clock Frequency Range | 0 MHz to 20 MHz |
| Compliance Standards | Electrical gear protection, EMC standards |
| Maintenance Phase Start Date | March 31, 2022 |
Question 1: What’s the part number of the PCI-6284?
Answer 1: 779110-01
Question 2: How many analog inputs does the PCI-6284 have?
Answer 2: 32
Question 3: What is the analog trigger accuracy of the PCI-6284?
Answer 3: ±1%
Question 4: When did the maintenance phase for PCI-6284 start?
Answer 4: March 31, 2022
Question 5: What are the internal base clock frequencies of the PCI-6284?
Answer 5: 0.1 MHz, 20 MHz, 80 MHz