Description
“`html
The PCI-6561 is a Digital Waveform Generator manufactured by National Instruments. This device is designed to cater to a variety of digital testing and simulation needs with its robust set of features.
It comes with multiple part numbers including 778991-01, 778991-02, and 778991-03, ensuring versatility for different configurations and requirements. The PCI-6561 is capable of reaching a maximum frequency of 100 MHz and is equipped with 16 data channels, providing ample bandwidth for generating complex waveforms and patterns.
One of the key features of the PCI-6561 is its synchronization capability, which allows for precise timing and alignment with other instruments and signals. The device supports various signal generation sources including an On Board clock, CLK IN, and STROBE, offering flexibility in signal sourcing. The On-Board Clock Frequency Range spans from 48 Hz to 100 MHz, while the CLK IN Frequency Range covers 20 kHz to 100 MHz, and the STROBE Frequency Range matches the On-Board range, providing a wide array of frequency options for signal generation.
The clock resolution is impressively fine at 10 ps, allowing for high-precision signal timing. The typical lock time is around 400 ms, and the device features a reference clock frequency range of 10 MHz ± 50 ppm. It supports a duty cycle range from 25% to 75%, catering to a wide variety of waveform shapes.
For software compatibility, the PCI-6561 uses NI-HSDIO driver software and is compatible with several programming environments including LabVIEW, LabWindows/CVI, Measurement Studio, Microsoft Visual C/C++, and .NET. Configuration and testing can be performed using the
Question 1: What is the max frequency of the PCI-6561? Question 2: How many data channels does the PCI-6561 have? Question 3: Can the PCI-6561 synchronize with other instruments? Question 4: What driver software does the PCI-6561 use? Question 5: What is the clock resolution of the PCI-6561?
Specification
Detail
Part Numbers
778991-01, 778991-02, 778991-03
Model
PCI-6561
Manufacturer
National Instruments
Type
Digital Waveform Generator
Maximum Frequency
100 MHz
Data Channels
16
Synchronization Capability
Yes
Signal Generation Sources
On Board clock, CLK IN, STROBE
On-Board Clock Frequency Range
48 Hz to 100 MHz
CLK IN Frequency Range
20 kHz to 100 MHz
STROBE Frequency Range
48 Hz to 100 MHz
Clock Resolution
10 ps
Typical Lock Time
400 ms
Reference Clock Frequency Range
10 MHz ± 50 ppm
Duty Cycle Range
25% to 75%
Driver Software
NI-HSDIO
Compatible Software Packages
LabVIEW, LabWindows/CVI, Measurement Studio, Microsoft Visual C/C++, .NET
Configuration Tool
Measurement & Automation Explorer (MAX)
Trigger Modes
Multiple
Typical Warm Time
15 minutes
Frequency Accuracy
± 100 ppm
Weight
410 g
Dimensions (Wx
Answer 1: 100 MHz
Answer 2: 16
Answer 3: Yes, it supports synchronization.
Answer 4: NI-HSDIO
Answer 5: 10 ps