The PCI-MIO-16XE-10, with part number 191452A-01 (also known as PCI-6030E, 777384-01), is a high-performance PC-based Multifunction DAQ designed for a wide range of applications. This device is equipped with 8 digital I/O lines that are 5 V CMOS/TTL compatible, making it versatile for integrating with various digital devices.
It features two 24-bit up/down counters, allowing for precise measurement and control tasks. For output purposes, it provides two voltage outputs with 16 bits resolution, ensuring high accuracy in signal generation. The DAQ also offers 16 analog inputs, which can be configured in either differential or single-ended mode, accommodating a wide range of sensor types.
The device connects via a 68-pin male SCSI-II type I/O connector, ensuring robust and reliable data transmission. It is powered directly by the host PCI slot, eliminating the need for external power supplies. With a maximum sample rate of 100,000 samples per second, it can handle high-speed data acquisition tasks efficiently.
Software compatibility includes NIDAQ 7, LabVIEW, Measurement Studio, and LabWindows/CVI, offering flexibility in development environments. It also features a FIFO buffer for voltage outputs with a capacity of 2,048 samples, enhancing its data handling capabilities. Self-calibration is software-controlled, though external calibration is recommended at least once a year to maintain accuracy.
With dimensions of 6.9 x 4.2 inches and weighing just 7.4 oz, this DAQ unit is compact and lightweight. It operates within a temperature range of 0 to 50 °C and can be stored in temperatures ranging from –20 to 70 °C. The device can function in environments with relative humidity ranging from 10 to 90% RH (non-condensing). It is designed to meet IEC 61010 electrical safety standards, ensuring safe operation in various settings.
| Feature | Description |
|---|---|
| Part Number | 191452A-01 (Also known as PCI-6030E, 777384-01) |
| Category | PC-based Multifunction DAQ |
| Model | PCI-MIO-16XE-10 |
| Digital I/O Lines | 8 (5 V CMOS/TTL compatible) |
| Counters | Two 24-bit up/down |
| Analog Outputs | 2 voltage outputs (16 bits resolution) |
| Analog Inputs | 16 (can be configured in differential or single-ended mode) |
| I/O Connector | 68-pin male SCSI-II type |
| Power Requirement | Powered by host PCI slot |
| Maximum Sample Rate | 100,000 samples per second |
| Software Compatibility | NIDAQ 7, LabVIEW, Measurement Studio, LabWindows/CVI |
| FIFO Buffer for Voltage Outputs | 2,048 samples |
| Self-Calibration | Software controlled, requires external calibration at least once a year |
| Dimensions | 6.9 x 4.2 inches |
| Weight | 7.4 oz |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | –20 to 70 °C |
| Relative Humidity Range | 10 to 90% RH (non-condensing) |
| Electrical Safety Standards | IEC 61010
Question 1: What is the part number for the PCI-MIO-16XE-10? Question 2: How many analog inputs does the PCI-MIO-16XE-10 have? Question 3: What is the max sample rate of the PCI-MIO-16XE-10? Question 4: What kind of I/O connector does the DAQ use? Question 5: What software is compatible with the PCI-MIO-16XE-10? |