Description
The product comes with part numbers 780264-01, 779521-01, and 780264-02, designed to cater to a variety of needs and applications. Each unit features four channels, ensuring versatile data acquisition capabilities. The system boasts an impressive sample rate of 50 kS/s per channel, allowing for high-speed data capture and analysis.
With an ADC resolution of 24 bits, users are guaranteed highly accurate and detailed measurements. The product offers flexible connectivity options, including RJ-50 and DSUB connectors, facilitating easy integration into existing setups. A notable feature is the conformal coating, available on part number 780264-02, which provides additional protection for the hardware in challenging environments.
The system is engineered to ensure zero inter-channel phase delay, guaranteeing precise timing and synchronization between channels. It also offers transient isolation of 60 VDC, 1000 Vrms, providing robust protection against voltage spikes and surges. The remote sensing capability enhances measurement accuracy by compensating for voltage drops in the test leads.
Shunt calibration is supported, allowing for easy and accurate calibration of the system. The product is compatible with a wide range of software, including NI-DAQmx 8.1 or later, LabVIEW, LabWindows/CVI, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, and Borland C++, ensuring seamless integration into various development environments.
For optimal performance, it is recommended to calibrate the product annually or every two years, maintaining accuracy and reliability over time.
| Specification | Detail |
|---|---|
| Part Numbers | 780264-01, 779521-01, 780264-02 |
| Channels | 4 |
| Sample Rate | 50 kS/s per channel |
| ADC Resolution | 24 bits |
| Connectivity Options | RJ-50, DSUB |
| Conformal Coating | Available on part number 780264-02 |
| Inter-Channel Phase Delay | Zero |
| Transient Isolation | 60 VDC, 1000 Vrms |
| Remote Sensing Capability | Yes |
| Shunt Calibration | Supported |
| Software Compatibility | NI-DAQmx 8.1 or later, LabVIEW, LabWindows/CVI, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, Borland C++ |
| Recommended Calibration Period | Annually or every two years |
Question 1: What is the sample rate of the NI-9237?
Answer 1: 50 kS/s per channel
Question 2: What ADC resolution does the NI-9237 offer?
Answer 2: 24 bits
Question 3: Does the NI-9237 support shunt calibration?
Answer 3: Yes
Question 4: What type of connectors does the NI-9237 use?
Answer 4: RJ-50 and DSUB
Question 5: How often should the NI-9237 be calibrated?
Answer 5: Annually or every two years