Description
The NI-9237 is a high-precision data acquisition device with a range of part numbers including 780264-01, 779521-01, and 780264-02. This model is designed with 4 channels, each capable of a sample rate of 50 kS/s (kilo-samples per second) to ensure detailed and rapid data collection. The accuracy of data is further enhanced by its 24-bit ADC (Analog-to-Digital Converter) resolution, providing high-definition data outputs for precise analysis.
For flexible connectivity options, the NI-9237 comes equipped with both RJ-50 and DSUB connectors, allowing for easy integration into various setups. Notably, the part number 780264-02 variant is conformal coated, offering additional protection in challenging environments. Safety and reliability are paramount, as highlighted by its isolation rating of 60 VDC, with a 1000 Vrms transient capability, ensuring the device operates safely even under unexpected conditions.
Compatibility with software is versatile, supporting NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, and various programming languages such as Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, and Borland C++. This ensures that the device can be easily integrated into existing systems without the need for extensive modifications.
Maintaining the NI-9237’s accuracy over time is facilitated by a recommended calibration interval of either annually or biennially, depending on usage patterns and precision requirements. This routine calibration ensures that the device continues to deliver accurate and reliable data over its operational lifespan.
| Specification | Detail |
|---|---|
| Part Numbers | 780264-01, 779521-01, 780264-02 |
| Model | NI-9237 |
| Channels | 4 |
| Sample Rate | 50 kS/s per channel |
| ADC Resolution | 24 bits |
| Connectivity Options | RJ-50, DSUB connectors |
| Conformal Coated | 780264-02 only |
| Isolation | 60 VDC, 1000 Vrms transient |
| Software Compatibility | NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, Borland C++ |
| Calibration Interval | Recommended annually or every two years |
Question 1: What is the sample rate of the NI-9237 per channel?
Answer 1: 50 kS/s
Question 2: What ADC resolution does the NI-9237 have?
Answer 2: 24-bit
Question 3: Are there conformal coated versions of the NI-9237?
Answer 3: Yes, part number 780264-02
Question 4: What is the isolation rating of the NI-9237?
Answer 4: 60 VDC, 1000 Vrms transient
Question 5: What software is compatible with the NI-9237?
Answer 5: NI-DAQmx 8.1 or later, LabVIEW, etc.