Description
The product with the part number 778572-12 is categorized as PXI Switches and is specifically the model PXI-2512. It is designed as a 7-Channel device, capable of handling a maximum switching current of 10 A and a maximum pulse current of 50 A for a duration of up to 600 μs. The device can operate with a maximum switching voltage of 50 VDC and 30 VACrms.
It features an overcurrent detection limit set typically at 10.5 A, with an overcurrent detection delay of 20 ms. Connection interfaces include two DSUB, 8 position male front panel connectors. To facilitate immediate usage, it comes with one DB8F-40A Cable for 8-pin DSUB and another DB8F-40A Cable for connection to the bare wire.
The power consumption rates are 1.0 W at 3.3 V and 13.0 W at 5 V, making it an efficient choice for various applications. Its form factor is designed as a 3U, two slot, PXI module, providing a compact yet powerful solution for your switching needs. The unit weighs 403 g (14.2 oz), offering a robust and reliable performance in a manageable size.
| Feature | Specification |
|---|---|
| Part Number | 778572-12 |
| Category | PXI Switches |
| Model | PXI-2512 |
| Channels | 7-Channel |
| Maximum Switching Current | 10 A |
| Maximum Pulse Current | 50 A (for 600 μs max) |
| Maximum Switching Voltage | 50 VDC, 30 VACrms |
| Overcurrent Detection Limit | 10.5 A typical |
| Overcurrent Detection Delay | 20 ms |
| Connectors | Two DSUB, 8 position male front panel connectors |
| Included Cables | One DB8F-40A Cable (for 8-pin DSUB), One DB8F-40A Cable (to the bare wire) |
| Power Consumption | 1.0 W at 3.3 V, 13.0 W at 5 V |
| Form Factor | 3U, two slot, PXI module |
| Weight | 403 g (14.2 oz) |
| Dimensions
Question 1: What is the max switching current of the PXI-2512? Answer 1: 10 A Question 2: How many channels does the PXI-2512 have? Question 3: What type of connectors does the PXI-2512 use? Question 4: What is the maximum pulse current of the PXI-2512? Question 5: What are the power consumption rates of the PXI-2512? |