img

193420B-01L

The PXI-2510 is a 68-channel, 2 A PXI Signal Insertion Switch Module designed for electronic reliability tests and HIL applications.

In Stock | Ships Today

img

    Description

    “`html

    The National Instruments PXI-2510 PXI Signal Insertion Switch Module, with part number 193420B-01L (778572-10), falls under the category of PXI Switches. This module is designed for applications such as electronic reliability tests and hardware-in-the-loop (HIL), making it a versatile component for various testing environments.

    The PXI-2510 model boasts a 68-Channel, 2 A configuration, providing ample capacity for complex testing scenarios. It features feedthrough channels, short/open to fault buses, and the ability to simulate interrupted/open connections, shorts to battery voltages, shorts between pins, and shorts to ground. These features make the PXI-2510 an invaluable tool for testing and simulating real-world electrical faults.

    Integration with LabVIEW is seamless, making the module ideal for FADECs, ECUs, and control systems validation when controlled via the LabVIEW Real-Time Module. This integration ensures that users can easily manage and automate their testing processes, enhancing efficiency and accuracy.

    The module’s pulse width recognition is less than 150 ns with digital filtering disabled, allowing for precise timing measurements. It utilizes a non-latching electromechanical relay with a typical actuation time of 1 ms. The mechanical relay life is rated at 1×108 cycles, and the electrical relay life can reach up to 5×105 cycles at 30 V, 1 A; and 1×105 cycles at 30 V, 2 A, ensuring long-term reliability and performance.

    The PXI-2510 connects via a 160 DIN 41612, male connector and is designed to fit in a 3U, one slot, PXI module form factor. Its dimensions are 18.8 cm x 2.0 cm x 13.0 cm and it weighs 12.6 oz., making it compact

    Specification Details
    Part Number 193420B-01L (778572-10)
    Category PXI Switches
    Model PXI-2510
    Description National Instruments PXI-2510 PXI Signal Insertion Switch Module
    Application Electronic reliability tests, Hardware-in-the-loop (HIL)
    Channels 68-Channel, 2 A
    Features Feedthrough channels, Short/Open to fault buses, Simulation of interrupted/open connections, shorts to battery voltages, shorts between pins, shorts to ground
    Integration with LabVIEW Ideal for FADECs, ECUs, and control systems validation when controlled via LabVIEW Real-Time Module
    Pulse Width Recognition < 150 ns with digital filtering disabled
    Relay Type Non-latching electromechanical relay
    Actuation Time 1 ms (typical)
    Mechanical Relay Life 1×108 cycles
    Electrical Relay Life 5×105 cycles at 30 V, 1 A; 1×105 cycles at 30 V, 2 A
    Connector 160 DIN 41612, male
    Form Factor 3U, one slot, PXI module
    Weight 12.6 oz.
    Dimensions 18.8 cm x 2.0 cm x 13.0 cm
    Power

    Question 1: What is the PXI-2510 designed for?
    Answer 1: Electronic reliability tests and HIL applications.

    Question 2: How many channels does the PXI-2510 have?
    Answer 2: 68 channels.

    Question 3: What is the current rating of PXI-2510?
    Answer 3: 2 A.

    Question 4: Can the PXI-2510 integrate with LabVIEW?
    Answer 4: Yes, it has seamless LabVIEW integration.

    Question 5: What is the actuation time of PXI-2510’s relay?
    Answer 5: Typically 1 ms.