Description
The product with a part number 153696A-01L falls under the category of PXI Switches, specifically the model PXI-2520. This model is described as the NI PXI-2520 80-Channel 2A SPST Relay Module, which is a general-purpose switching module designed for various applications.
Its relay type is characterized as single-pole, single-throw (SPST) independent A-frame type relays, ensuring reliable operation for the intended applications. The module offers software programmability, allowing for flexible and adaptable usage across different scenarios. Additionally, it supports relay account tracking, providing valuable insights into the operation and maintenance of the system.
The primary applications of this module include Automated Test Equipment (ATE), control of heaters, lights, fans, and more, showcasing its versatility in handling different tasks. However, it is important to note that it needs additional protection for switching inductive loads, ensuring the longevity and safety of the device.
Concerning its technical aspects, the module maintains a low DC path resistance throughout the life of the relay, which might increase towards the end of its life cycle. The power cycle process for this module necessitates the complete removal and discharge of power, highlighting the importance of proper power management. Lastly, the module’s memory requires energy to maintain stored information, with contents being lost when power is removed, indicating the need for consistent power supply or backup solutions.
| Specification | Detail |
|---|---|
| Part Number | 153696A-01L |
| Category | PXI Switches |
| Model | PXI-2520 |
| Description | NI PXI-2520 80-Channel 2A SPST Relay Module |
| Type | General-Purpose Switching Module |
| Relay Type | Single-pole, Single-throw (SPST) Independent A-frame Type Relays |
| Software Programmability | Yes |
| Relay Account Tracking | Supported |
| Application | Automated Test Equipment (ATE), Control of Heaters, Lights, Fans |
| Protection | Needs Additional Protection for Switching Inductive Loads |
| DC Path Resistance | Low for Life of the Relay, Increases at End of Life |
| Power Cycle Process | Requires Complete Power Removal and Discharge |
| Memory | Requires Energy to Maintain Stored Information, Contents Lost When Power Removed |
Question 1: What is the part number of the NI PXI-2520?
Answer 1: 153696A-01L
Question 2: What type of relays does the PXI-2520 use?
Answer 2: SPST independent A-frame type
Question 3: Can the PXI-2520 track relay usage?
Answer 3: Yes, it supports relay account tracking.
Question 4: Is the PXI-2520 suitable for switching inductive loads?
Answer 4: No, it requires additional protection.
Question 5: What happens to the PXI-2520’s memory when power is removed?
Answer 5: The memory contents are lost.