Description
“`html
The NI PXI-2533 4×64 SSR Matrix Module is identified by part number 197805A-01L, which is incorrectly noted in the description; the correct part number is 778572-33. This module falls under the category of PXI Switches and is designed to offer exceptional performance and reliability.
The PXI-2533 utilizes Solid-State Relays (SSRs) and boasts a 1-Wire, 256-Crosspoint PXI Matrix Switch Module configuration. This setup enables a maximum switching voltage of ±55 VDC, 30 VACrms, with a maximum switching power of 55 W and a maximum switching current of 1 A.
Its DC isolation resistance is impressive, standing at >2 GΩ, typical, while the path resistance is noted to be 2 µV, typical and 1 Ω, typical total row-to-column. The module’s bandwidth exceeds 1.5 MHz (typical) for a single crosspoint in a 50 Ω system, ensuring high-speed operations.
The operating time of the PXI-2533 is 724 µs (typical), 2.5 ms (maximum), and it features a scanning rate of 400 crosspoints/s at 1 A and <20 V. This technical specification underscores the module’s efficiency and speed, making it an ideal choice for a variety of high-performance switching applications.
“`
| Specification | Details |
|---|---|
| Part Number | 197805A-01L (Incorrect in Description, Correct is 778572-33) |
| Category | PXI Switches |
| Model | PXI-2533 |
| Description | NI PXI-2533 4×64 SSR Matrix Module |
| Relay Type | Solid-State Relays (SSRs) |
| Configuration | 1-Wire, 256-Crosspoint PXI Matrix Switch Module |
| Maximum Switching Voltage | ±55 VDC, 30 VACrms |
| Maximum Switching Power | 55 W |
| Maximum Switching Current | 1 A |
| DC Isolation Resistance | >2 GΩ, typical |
| Path Resistance | 2 µV, typical and 1 Ω, typical total row-to-column |
| Bandwidth | >1.5 MHz (typical) single crosspoint in a 50 Ω system |
| Operating Time | 724 µs (typical), 2.5 ms (maximum) |
| Scanning Rate | 400 crosspoints/s at 1 A and <20 V
Question 1: What is the correct part number for the NI PXI-2533? Answer 1: The correct part number is 778572-33. Question 2: What type of relays does the PXI-2533 use? Question 3: How many crosspoints does the PXI-2533 support? Question 4: What is the maximum switching voltage of the PXI-2533? Question 5: What is the typical bandwidth of the PXI-2533? |