Description
The PXI-2575 is identified by its part number 778572-75 and falls under the category of PXI Switches. This model is a 196 ch Multiplexer, designed to enhance the efficiency and versatility of test systems. It features a unique switch configuration that includes a 1-wire 196 x 1, 2-wire 95 x 1, and 2-wire 98 x 1 Multiplexer, providing a wide range of connection possibilities for various test scenarios.
The PXI-2575 utilizes Electromechanical Relays, ensuring reliable performance with a relay life of approximately 105 operations at rated load. The switch’s bandwidth reaches up to 20 MHz, allowing for the handling of signals with minimal loss of fidelity. Each channel of this switch can support a maximum switching power of 60 W, 62.5 VA (DC to 60 Hz), accommodating a broad spectrum of devices and applications.
One of the notable features of the PXI-2575 is its Relay Count Tracking capability, which offers users the ability to monitor the operational status and lifecycle of the relays, enhancing maintenance and reliability. The device connects via a 200 POS LFH Matrix 50 I/O connector, ensuring a secure and stable connection for accurate testing results.
While the PXI-2575 excels in many areas, it is not recommended for 2-wire resistance measurements, as this may not yield the most accurate results due to the specific design and configuration of the switch. The typical relay operating time is impressively quick at 1 ms, with the maximum relay operating time capped at 3.4 ms. Furthermore, the relay contact material is made of silver, gold, ensuring excellent conductivity and reliability for a wide range of applications.
| Specification | Detail |
|---|---|
| Part Number | 778572-75 |
| Category | PXI Switches |
| Model | PXI-2575 |
| Description | 196 ch Multiplexer |
| Switch Configuration | 1-wire 196 x 1, 2-wire 95 x 1, 2-wire 98 x 1 Multiplexer |
| Relay Type | Electromechanical Relays |
| Relay Life | Approx. 105 operations at rated load |
| Switch Bandwidth | 20 MHz |
| Maximum Switching Power | 60 W, 62.5 VA (DC to 60 Hz) per channel |
| Relay Count Tracking | Yes |
| Connector Type | 200 POS LFH Matrix 50 I/O connector |
| Not Recommended For | 2-wire resistance measurements |
| Typical Relay Operating Time | 1 ms |
| Maximum Relay Operating Time | 3.4 ms |
| Relay Contact Material | Silver, gold
Question 1: What is the part number for the PXI-2575? Question 2: How many channels does the PXI-2575 support? Question 3: What is the max bandwidth of the PXI-2575? Question 4: What is the max switching power of PXI-2575 per channel? Question 5: Is the PXI-2575 recommended for 2-wire resistance measurements? |