Description
The National Instruments PXI-2575 is a high-performance PXI Multiplexer Switch Module, designed to meet the needs of a variety of signal switching applications. With a part number of 778572-75, this module falls under the category of PXI Switches.
The PXI-2575 features various topology options, including a 1-wire 196 x 1, a 2-wire 95 x 1, and a 2-wire 98 x 1 Multiplexer, providing flexibility for different testing requirements. It utilizes electromechanical, socketed relays to ensure reliable performance over its lifespan. The electrical life of these relays is estimated to be approximately 105 operations, showcasing the module’s durability.
With a switch bandwidth of 20 MHz, this module can handle a wide range of frequencies, making it suitable for various applications. It supports a maximum switching power of 60 W, 62.5 VA (DC to 60 Hz) per channel, ensuring it can manage significant power levels for its size. Additionally, the PXI-2575 includes a relay count tracking feature, enhancing its operational reliability by monitoring relay usage.
The module utilizes a 200 POS LFH Matrix 50 I/O connector, providing a secure and reliable connection for your testing setup. Although it is not recommended for 2-wire resistance measurements, its versatility in other applications makes it a valuable addition to any test system. The typical relay operating time is 1 ms, with a maximum relay operating time of 3.4 ms, ensuring quick and efficient switching operations.
| Specification | Details |
|---|---|
| Part Number | 778572-75 |
| Category | PXI Switches |
| Model | PXI-2575 |
| Description | National Instruments PXI-2575 PXI Multiplexer Switch Module |
| Topology Options | 1-wire 196 x 1, 2-wire 95 x 1, 2-wire 98 x 1 Multiplexer |
| Relay Type | Electromechanical, Socketed |
| Electrical Life of Relays | Approximately 105 operations |
| Switch Bandwidth | 20 MHz |
| Maximum Switching Power | 60 W, 62.5 VA (DC to 60 Hz) per channel |
| Relay Count Tracking Feature | Yes |
| Connector Type | 200 POS LFH Matrix 50 I/O connector |
| Recommended for 2-wire Resistance Measurements | No |
| Typical Relay Operating Time | 1 ms |
| Maximum Relay Operating Time | 3.4 ms |
| Relay Contact
Question 1: What is the part number of the PXI-2575? Question 2: What switch bandwidth does the PXI-2575 support? Question 3: What is the electrical life of the PXI-2575’s relays? Question 4: What is the maximum switching power of the PXI-2575? Question 5: What connector type does the PXI-2575 use? |