Description
The NI PXI-4070 FlexDMM Digital Multimeter, part number 778274-04, is a versatile and powerful instrument designed for precision measurements. This device integrates FlexDMM technology, enabling it to deliver exceptional performance across a wide range of applications.
With a digit resolution of 6.5 and the capability to achieve a sampling rate of up to 1.8 MS/s, the PXI-4070 is equipped to handle demanding measurement tasks. It boasts a maximum resolution of 23 bits, ensuring high accuracy in readings.
The PXI-4070 is compatible with several programming interfaces, including C/C++, .NET, Visual Basic, LabVIEW, and LabWindows/CVI. This wide range of compatibility allows for flexible system integration and application development.
In terms of system features, the PXI-4070 offers impressive specifications for both DC and AC measurements. For DC systems, it provides a range/function change rate of 100/s, an auto range time of 50 ms, a trigger latency of 2 µs, and a maximum trigger rate of 6kHz. AC system specifications include a range/function change rate of 10/s, an auto range time of 250 ms, and a maximum trigger rate of 1kHz.
The device also supports self-calibration, ensuring accurate measurements across its operating temperature range of 0 to 55 degrees Celsius. Furthermore, the PXI-4070’s maintenance and calibration services are supported by Apex Waves for both purchase and repairs. Calibration services are available, with the option of NIST accredited calibration through a third party.
| Specification | Detail |
|---|---|
| Part Number | 778274-04 |
| Model | PXI-4070 |
| Description | NI PXI-4070 FlexDMM Digital Multimeter |
| Digit Resolution | 6.5 |
| FlexDMM Technology | Yes |
| Sampling Rate | Up to 1.8 MS/s |
| Maximum Resolution | 23 bits |
| Programming Interface Compatibility | C/C++, .NET, Visual Basic, LabVIEW, LabWindows/CVI |
| DC System Features | Range/Function Change: 100/s, Auto Range Time: 50 ms, Trigger Latency: 2 µs, Max Trigger Rate: 6kHz |
| AC System Features | Range/Function Change: 10/s, Auto Range Time: 250 ms, Trigger Latency: µs, Max Trigger Rate: 1kHz |
| Self-Calibration | Supported (0 to 55 degrees Celsius operating temperature range) |
| Maintenance Status | Supported by Apex Waves for purchase and repairs |
| Calibration | Available, with NIST accredited option through a 3rd party |
Question 1: What is the digit resolution of the NI PXI-4070?
Answer 1: 6.5 digits
Question 2: What is the max sampling rate of the PXI-4070?
Answer 2: Up to 1.8 MS/s
Question 3: What programming languages is PXI-4070 compatible with?
Answer 3: C/C++, .NET, Visual Basic, LabVIEW, LabWindows/CVI
Question 4: What is the max trigger rate for DC measurements on PXI-4070?
Answer 4: 6kHz
Question 5: Does the PXI-4070 support self-calibration?
Answer 5: Yes