Description
“`html
The PXI-4071 is a high-precision PXI Multimeter that comes with a part number of 191485M-02L (Alternate: 778271-01). This device stands out for its exceptional performance in various measurement capabilities. It is described as a 7 1/2 Digit FlexDMM which includes a digitizer with a sample rate of up to 1.8 MS/s, and is capable of handling voltages up to 1000V and currents ranging from ±1 pA to 3 A.
When it comes to voltage measurement, the PXI-4071 can measure within a range of ±10 nV to 1000 V. For current measurement, the range is quite extensive as well, spanning from ±1 pA to 3 A. The resistance measurement capabilities of this device are also noteworthy, with a range from 10 µΩ to 5 GΩ. This makes the PXI-4071 versatile for a wide array of applications.
The digitizer sample rate of this multimeter can reach up to 1.8 MS/s, providing high-speed data acquisition. In terms of DC reading rates, the device can achieve 7 S/s at 7 1/2 digits, and 10 kS/s at 4 1/2 digits, ensuring accurate and fast measurements. The AC coupled auto range time is 250 ms, with a range/function change rate of 10/s, allowing for quick adjustments during operations.
Moreover, the PXI-4071 exhibits a very low trigger latency of 2 µs, and a maximum trigger rate of 1 kHz, enhancing its performance in automated testing environments. However, it is important to note that the device requires a warm-up time of 1 hour to ensure accurate measurements. The availability of calibration for this multimeter ensures that it maintains its precision over time, making it a reliable choice for demanding applications
| Specification | Detail |
|---|---|
| Part Number | 191485M-02L (Alternate: 778271-01) |
| Category | PXI Multimeters |
| Model | PXI-4071 |
| Description | 7 1/2 Digit FlexDMM (1.8 MS/s Digitzer, 1000V, 1pA-3A) |
| Voltage Measurement Range | ±10 nV to 1000 V |
| Current Measurement Range | ±1 pA to 3 A |
| Resistance Measurement Range | 10 µΩ to 5 GΩ |
| Digitizer Sample Rate | Up to 1.8 MS/s |
| DC Reading Rates | 7 S/s at 7 1/2 digits, 10 kS/s at 4 1/2 digits |
| AC Coupled Auto Range Time | 250 ms |
| Range/Function Change | 10/s |
| Trigger Latency and Maximum Trigger Rate | 2 µs, 1 kHz |
| Warm-up Time | 1 hour |
| Calibration Availability | Question 1: What is the sample rate of the PXI-4071 digitizer? Answer 1: Up to 1.8 MS/s Question 2: What is the voltage range of the PXI-4071? Question 3: What is the maximum current the PXI-4071 can measure? Question 4: How long is the warm-up time for accurate measurements? Question 5: What is the part number of the PXI-4071? |