Description
The NI PXI-4072 is a multifunctional device that serves as a 6½-digit multimeter, LCR meter, and an Isolated digitizer. It features part numbers 191485G-03L, 778270-01 and falls under the category of PXI Multimeters. This model is specifically designed to cater to a wide range of electrical measurements with high precision and flexibility.
The PXI-4072 boasts a maximum sample rate of 1.8 MS per second, allowing for rapid data acquisition and processing. It supports a DC Voltage Range from -300 V to 300 V and a DC Current Range from -1 A to 1 A, making it versatile for various testing scenarios. The device’s resolution is at an impressive 6.5 digit, ensuring highly accurate readings.
With capabilities to switch DC Range/Function at a rate of 100/s and AC Range/Function at 10/s, the PXI-4072 ensures efficient performance in dynamic environments. It operates within an ambient temperature range of 0 °C to 55 °C, further underscoring its reliability under different working conditions.
Compatibility with NI-DMM driver software enhances its functionality, allowing for seamless integration with existing systems. The device’s computer configuration requirements are quite comprehensive, including support for PCI slots, various PCI Express slots, USB 2.0/1.1 slots, PXI, PXI/CompactPCI, PXI/SCXI combination chassis, alongside necessary chassis documentation and a controller.
Maintenance for the PXI-4072 is readily available for purchase and repairs by Apex Waves. Additionally, calibration services are offered, with options for either NIST accredited calibrations or basic in-house calibration, ensuring that the device maintains its precision and accuracy over time.
| Feature | Description |
|---|---|
| Part Number | 191485G-03L, 778270-01 |
| Category | PXI Multimeters |
| Model | PXI-4072 |
| Description | NI PXI-4072 6 1/2 Digit FlexDMM, LCR (1.8 MS/s Digitzer, 300V, 1A) |
| Functionality | 6½-digit multimeter, LCR meter, Isolated digitizer |
| Maximum Sample Rate | 1.8 MS per second |
| DC Voltage Range | -300 V to 300 V |
| DC Current Range | -1 A to 1 A |
| Resolution | 6.5 digit |
| DC Range/Function Change | 100/s |
| AC Range/Function Change | 10/s |
| Operating Ambient Temperature Range | 0 °C to 55 °C |
| Driver Software | NI-DMM |
| Computer Configuration Requirements | PCI slot, x1/x4/x8/x16 PCI Express slot, USB 2.0/1.1 slot, PXI, PXI/CompactPCI, PXI/SCXI combination chassis, chassis documentation, and a controller |
| Maintenance Status | Available for purchase and repairs by Apex Waves |
| Calibration | Available, with options for NIST accredited calibrations or basic in-house calibration |
Question 1: What is the max sample rate of NI PXI-4072?
Answer 1: 1.8 MS/s
Question 2: What voltage range does the PXI-4072 support?
Answer 2: -300V to 300V
Question 3: Can the PXI-4072 perform LCR measurements?
Answer 3: Yes, it has LCR meter functionality.
Question 4: What are the ambient operation conditions for the PXI-4072?
Answer 4: 0 °C to 55 °C
Question 5: Is calibration service available for the PXI-4072?
Answer 5: Yes, both NIST and basic calibrations.