Description
The Part Number for this device is 188524L-07L, indicating a specific configuration or version within its category. This device falls under the Category of PXI Oscilloscopes/Digitizers, specifically the model PXI-5122. It is designed to offer precision and versatility in various testing and measurement scenarios.
The Digitizer Speed of the PXI-5122 is capable of reaching up to 100 MS/s, allowing for high-speed data acquisition. This model offers various Memory Options, including configurations of 8 MB (778756-01), 32 MB (778756-02), 256 MB (778756-03), and 512 MB (778756-04), providing flexibility in storage capacity based on the application requirements.
With an ADC Resolution of 14-bit, the PXI-5122 delivers high fidelity in signal conversion, ensuring detailed and accurate measurements. The Spurious Free Dynamic Range is noted to be 75 dBc, and the Signal-to-Noise Ratio stands at 62 dB, which are critical parameters indicating the device’s performance in minimizing noise and maximizing signal clarity.
The device’s Input Impedance can be Software selectable between 50 Ω or 1 MΩ, allowing for flexibility in adapting to different signal sources. The Input Range spans from 200 mVpp to 20 Vpp, accommodating a wide variety of signal amplitudes. It also supports Seven Trigger Modes, enabling precise control over the timing of data acquisition.
Included are Filters for Anti-alias and noise, which are essential for maintaining signal integrity and reducing unwanted signal components. The Software Compatibility includes NI-SCOPE driver, LabVIEW, LabWindows/CVI, ensuring that the device
| Specification | Detail |
|---|---|
| Part Number | 188524L-07L |
| Category | PXI Oscilloscopes/Digitizers |
| Model | PXI-5122 |
| Digitizer Speed | 100 MS/s |
| Memory Options | 8 MB (778756-01), 32 MB (778756-02), 256 MB (778756-03), 512 MB (778756-04) |
| ADC Resolution | 14-bit |
| Spurious Free Dynamic Range | 75 dBc |
| Signal-to-Noise Ratio | 62 dB |
| Input Impedance | Software selectable 50 Ω or 1 MΩ |
| Input Range | 200 mVpp to 20 Vpp |
| Trigger Modes | Seven |
| Filters | Anti-alias and noise filters |
| Software Compatibility | NI-SCOPE driver, LabVIEW, LabWindows/CVI |
| Front Panel Connectors | 3 BNC female, 9-pin mini-circular DIN, 2 SMB jack |
| Calibration
Question 1: What is the speed of PXI-5122? Question 2: What is the ADC resolution of PXI-5122? Question 3: What input impedance options does PXI-5122 offer? Question 4: How many trigger modes does PXI-5122 support? Question 5: What software is compatible with PXI-5122? |